使用纳米点光激发发光剂量计(OSLD)进行腹部X线摄影时的入射皮肤剂量(ESD)和滤线器台面引起的反向散射剂量(BTI-BSD)

Entrance Skin Dose (ESD) and Bucky Table Induced Backscattered Dose (BTI-BSD) in Abdominal Radiography With nanoDot Optically Stimulated Luminescence Dosimeter (OSLD).

作者信息

Sayed Inayatullah Shah, Roslan Nurul Shuhada, Syed Waliullah Shah

机构信息

Department of Diagnostic Imaging and Radiotherapy, International Islamic University Malaysia, Kuantan Campus, Kuantan, MYS.

Department of Applied Sciences, Stanford International College, Mississauga, CAN.

出版信息

Cureus. 2023 Feb 3;15(2):e34585. doi: 10.7759/cureus.34585. eCollection 2023 Feb.

Abstract

In radiography, inconsistencies in patients' measured entrance skin dose (ESD) exist. There is no published research on the bucky table induced backscattered radiation dose (BTI-BSD). Thus, we aimed to ascertain ESD, calculate the BTI-BSD in abdominal radiography with a nanoDot OSLD, and compare the ESD results with the published data. A Kyoto Kagaku PBU-50 phantom (Kyoto, Japan) in an antero-posterior supine position was exposed, selecting a protocol used for abdominal radiography. The central ray of x-ray beam was pointed at the surface of abdomen at the navel, where a nanoDot dosimeter was placed to measure ESD. For the BTI-BSD, exit dose (ED) was determined by placing a second dosimeter on the exact opposite side (backside) of the phantom from the dosimeter used to determine (ESD) with and without bucky table at identical exposure parameters. The BTI-BSD was calculated as the difference between ED with and without bucky table. The ESD, ED, and BTI-BSD were measured in milligray (mGy). ESD mean values with and without bucky table were 1.97 mGy and 1.84 mGy, whereas ED values were 0.062 mGy and 0.052 mGy, respectively. Results show 2-26% lower ESD values with nanoDot OSLD. The BTI-BSD mean value was found to be approximately 0.01 mGy. A local dose reference level (LDRL) can be established using ESD data to safeguard patients from unnecessary radiation. In addition, to minimize the risk of BTI-BSD in patients in radiography, the search for the use or fabrication of a new, lower atomic number material for the bucky table is suggested.

摘要

在放射摄影中,患者测量的体表入射剂量(ESD)存在不一致性。目前尚无关于滤线栅台面产生的反向散射辐射剂量(BTI-BSD)的公开研究。因此,我们旨在确定ESD,使用纳米Dot OSLD计算腹部放射摄影中的BTI-BSD,并将ESD结果与已发表的数据进行比较。将一个京都科学PBU-50体模(日本京都)置于前后位仰卧位进行曝光,选择用于腹部放射摄影的方案。X射线束的中心线指向肚脐处的腹部表面,在该处放置一个纳米Dot剂量计来测量ESD。对于BTI-BSD,通过在与用于确定ESD的剂量计相对的体模另一侧(背面)放置第二个剂量计来确定出射剂量(ED),在相同的曝光参数下分别有无滤线栅台面的情况。BTI-BSD计算为有滤线栅台面和无滤线栅台面时ED的差值。ESD、ED和BTI-BSD以毫戈瑞(mGy)为单位进行测量。有滤线栅台面和无滤线栅台面时ESD的平均值分别为1.97 mGy和1.84 mGy,而ED值分别为0.062 mGy和0.052 mGy。结果显示使用纳米Dot OSLD时ESD值低2%-26%。发现BTI-BSD的平均值约为0.01 mGy。可以利用ESD数据建立局部剂量参考水平(LDRL),以保护患者免受不必要辐射。此外,为了将放射摄影中患者的BTI-BSD风险降至最低,建议寻找用于滤线栅台面的新的、原子序数更低的材料或制造此类材料。