Suppr超能文献

量化圆锥角膜眼角膜地形散光(CorT Total)。

Quantifying Corneal Topographic Astigmatism (CorT Total) in Keratoconic Eyes.

出版信息

J Refract Surg. 2023 Mar;39(3):206-213. doi: 10.3928/1081597X-20230103-03. Epub 2023 Mar 1.

Abstract

PURPOSE

To determine optimal corneal regions from which to derive corneal topographic astigmatism (CorT) in kerato-conic eyes.

METHODS

In this retrospective study, potential measures of corneal astigmatism are calculated from raw total corneal power data (179 eyes from 124 patients) from a corneal tomographer. The measures are derived from annular corneal regions varying in both extent and center position, and evaluated according to the variability of the ocular residual astigmatism (ORA) in the cohort. This variability is quantified by the ORArms, which is the root-mean-squared distance of the ORAs from their summated vector mean in double angle space. The lower the ORArms, the better the corneal astigmatism measure corresponds to manifest refractive cylinder.

RESULTS

Corneal astigmatism measures derived from regions centered on corneal vertex had ORArms values (mild: 1.07 diopters [D], moderate: 1.61 D, severe: 2.65 D) as low or lower than other measures derived from regions centered on thinnest point, corneal apex (front or back), or pupil center. Corneal astigmatism measures derived from a region centered 30% of the way toward thinnest point from corneal vertex appeared to have even lower ORArms values (mild: 1.05 D, moderate: 1.45 D, severe: 2.56 D). None of the corneal astigmatism measures corresponded closely with manifest refractive cylinder for severe keratoconus (ORArms > 2.50 D).

CONCLUSIONS

For keratoconic eyes, the CorT should be derived from an annular region centered 30% of the way toward thinnest point from corneal vertex, although when the keratoconus is mild, a standard corneal-vertex-centered CorT performs just as well. .

摘要

目的

确定圆锥角膜中用于获取角膜地形散光(CorT)的最佳角膜区域。

方法

在这项回顾性研究中,从角膜断层扫描仪的原始总角膜屈光力数据(来自 124 名患者的 179 只眼)中计算潜在的角膜散光测量值。这些测量值来自环形角膜区域,其范围和中心位置均有所不同,并根据队列中眼残余散光(ORA)的可变性进行评估。这种可变性通过 ORArms 量化,即ORA 与其总和向量均值在双角空间中的均方根距离。ORArms 越低,角膜散光测量值与表现折射圆柱越吻合。

结果

以角膜顶点为中心的区域得出的角膜散光测量值的 ORArms 值(轻度:1.07 屈光度 [D],中度:1.61 D,重度:2.65 D)与以最薄点、角膜顶点(前或后)或瞳孔中心为中心的区域得出的其他测量值一样低或更低。以距角膜顶点最薄点的 30%处为中心的区域得出的角膜散光测量值似乎具有更低的 ORArms 值(轻度:1.05 D,中度:1.45 D,重度:2.56 D)。对于严重的圆锥角膜,没有任何角膜散光测量值与表现折射圆柱紧密对应(ORArms > 2.50 D)。

结论

对于圆锥角膜眼,应从角膜顶点最薄点的 30%处开始的环形区域中得出 CorT,尽管当圆锥角膜较轻度时,标准的以角膜顶点为中心的 CorT 也能很好地发挥作用。