Department of Orthopedics, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China.
Department of Ultrasound, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China.
BMJ Open. 2023 Mar 10;13(3):e064838. doi: 10.1136/bmjopen-2022-064838.
Percutaneous pedicle screw placement (PPSP) is a minimally invasive procedure highly dependent on fluoroscopic guidance, which results in increased radiation exposure and prolonged operative time. Ultrasound can image the lumbar paravertebral anatomy and the needle trajectory in real time, which may help reduce the use of fluoroscopy and radiation dose in PPSP. We will conduct a parallel randomised controlled trial to mainly investigate the effect of ultrasound guidance in radiation reduction during PPSP.
A total of 42 patients will be recruited and randomly assigned to the intervention group and the control group at a 1:1 ratio. In the intervention group, we will use ultrasound in combination with fluoroscopy to guide the insertion of the Jamshidi needles. In the control group, PPSP will be performed under conventional fluoroscopic guidance. The primary outcomes are the cumulative fluoroscopy time (s), radiation dose (mGy) and exposure times of screw placement. The secondary outcomes are insertion time of guidewire, rate of pedicle perforation, rate of facet joint violation, visual analogue scale for back pain, Oswestry Disability Index and complications. The participants, outcome assessors and data analysts will be blinded to allocation.
The trial was approved by the research ethics committee of Shengjing Hospital, China Medical University. The results will be presented at academic seminars and submitted for publication in peer-reviewed journals.This study involves human participants and was approved by Research Ethics Committee of Shengjing Hospital, China Medical University reference number:2022PS704K. Participants gave informed consent to participate in the study before taking part.
ChiCTR2200057131.
经皮椎弓根螺钉置入术(PPSP)是一种高度依赖透视引导的微创手术,这会导致辐射暴露增加和手术时间延长。超声可以实时成像腰椎椎旁解剖结构和针道,这可能有助于减少 PPSP 中透视的使用和辐射剂量。我们将进行一项平行随机对照试验,主要研究超声引导在 PPSP 中减少辐射的效果。
将招募 42 名患者,并以 1:1 的比例随机分配到干预组和对照组。在干预组中,我们将使用超声结合透视引导Jamshidi 针的插入。在对照组中,将在常规透视引导下进行 PPSP。主要结局是累积透视时间(s)、辐射剂量(mGy)和螺钉置入的曝光次数。次要结局是导丝插入时间、椎弓根穿孔率、关节突关节侵犯率、腰背疼痛视觉模拟评分、Oswestry 残疾指数和并发症。参与者、结局评估者和数据分析师将对分组情况进行盲法。
该试验已获得中国医科大学盛京医院研究伦理委员会的批准。研究结果将在学术研讨会上进行报告,并提交给同行评议期刊发表。本研究涉及人类参与者,并已获得中国医科大学盛京医院研究伦理委员会的批准,注册号:2022PS704K。参与者在参与研究前已签署知情同意书。
ChiCTR2200057131。