Suppr超能文献

SMILE 术后近视性散光的程序化光学区对角膜屈光力的影响:向量分析。

The effects of programmed optical zones on achieved corneal refractive power with myopic astigmatism after small incision lenticule extraction (SMILE): a vector analysis.

机构信息

Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China.

Clinical College of Ophthalmology, Tianjin Eye Hospital, Tianjin Eye Institute, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Medical University, No 4. Gansu Road, He-Ping District, Tianjin, 300020, China.

出版信息

Int Ophthalmol. 2023 Jul;43(7):2493-2501. doi: 10.1007/s10792-023-02649-7. Epub 2023 Mar 11.

Abstract

PURPOSE

To evaluate the effects of different programmed optical zones (POZs) on achieved corneal refractive power (CRP) with myopic astigmatism after small incision lenticule extraction (SMILE).

METHODS

In total, 113 patients (113 eyes) were included in this retrospective study. The eyes were divided into two groups according to POZ: group A (6.5, 6.6, and 6.7 mm, n = 59) and group B (6.8, 6.9, and 7.0 mm, n = 54). Fourier vector analysis was applied to evaluate the error values between the attempted and achieved corneal refractive power (CRP). Alpins vector analysis was used to calculate surgically induced astigmatism (SIA), difference vector (DV), magnitude of error (ME), and astigmatism correction index (ACI). Multivariate regression analysis was performed to assess potential factors associated with the error values.

RESULTS

The error values in the group with large POZ were closer to zero, and significantly associated with the POZ at 2 and 4 mm of the cornea (β =  - 0.50, 95% confidence interval [CI] [- 0.80, - 0.20]; β =  - 0.37, 95% CI [- 0.63, - 0.10], P < 0.05, respectively). For the correction of astigmatism, the values of SIA, ME, and ACI were lower in group B than in group A (P < 0.05). The fitting curves between TIA and SIA were y = 0.83x + 0.19 (R = 0.84) and y = 1.05x + 0.04 (R = 0.90), respectively.

CONCLUSIONS

Smaller POZs resulted in higher error values between the achieved- and attempted-CRP in the SMILE procedure, which should be considered when performing surgery.

摘要

目的

评估不同编程光学区(POZ)对 SMILE 术后伴近视散光的角膜屈光力(CRP)的影响。

方法

本回顾性研究共纳入 113 例(113 只眼)患者。根据 POZ 将眼分为两组:A 组(6.5、6.6 和 6.7mm,n=59)和 B 组(6.8、6.9 和 7.0mm,n=54)。采用傅里叶向量分析评估目标角膜屈光力(CRP)与实际获得的 CRP 之间的误差值。Alpins 向量分析用于计算手术诱导的散光(SIA)、差异向量(DV)、误差幅度(ME)和散光矫正指数(ACI)。采用多元回归分析评估与误差值相关的潜在因素。

结果

大 POZ 组的误差值更接近 0,且与角膜 2mm 和 4mm 处的 POZ 显著相关(β=-0.50,95%置信区间[CI]:-0.80 至-0.20;β=-0.37,95%CI:-0.63 至-0.10,P<0.05)。在矫正散光方面,B 组的 SIA、ME 和 ACI 值均低于 A 组(P<0.05)。TIA 与 SIA 的拟合曲线分别为 y=0.83x+0.19(R=0.84)和 y=1.05x+0.04(R=0.90)。

结论

SMILE 术中 POZ 越小,实际获得的 CRP 与目标 CRP 之间的误差值越大,手术时应考虑这一点。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验