Suppr超能文献

ACR-ARS 全身放射治疗实践参数。

ACR-ARS Practice Parameter for the Performance of Total Body Irradiation.

机构信息

University of California, Irvine, Irvine, CA.

City of Hope 1500 East Duarte Road Duarte, CA.

出版信息

Am J Clin Oncol. 2023 May 1;46(5):185-192. doi: 10.1097/COC.0000000000000997. Epub 2023 Mar 13.

Abstract

OBJECTIVES

This practice parameter was revised collaboratively by the American College of Radiology (ACR) and the American Radium Society (ARS). This practice parameter provides updated reference literature regarding both clinical-based conventional total body irradiation and evolving volumetric modulated total body irradiation.

METHODS

This practice parameter was developed according to the process described under the heading The Process for Developing ACR Practice Parameters and Technical Standards on the ACR website ( https://www.acr.org/Clinical-Resources/Practice-Parameters-and-Technical-Standards ) by the Committee on Practice Parameters-Radiation Oncology of the ACR Commission on Radiation Oncology in collaboration with the ARS.

RESULTS

This practice parameter provides a comprehensive update to the reference literature regarding conventional total body irradiation and modulated total body irradiation. Dependence on dose rate remains an active area of ongoing investigation in both the conventional setting (where instantaneous dose rate can be varied) and in more modern rotational techniques, in which average dose rate is the relevant variable. The role of imaging during patient setup and the role of inhomogeneity corrections due to computer-based treatment planning systems are included as evolving areas of clinical interest notably surrounding the overall dose inhomogeneity. There is increasing emphasis on the importance of evaluating mean lung dose as it relates to toxicity during high-dose total body irradiation regimens.

CONCLUSIONS

This practice parameter can be used as an effective tool in designing and evaluating a total body irradiation program that successfully incorporates the close interaction and coordination among the radiation oncologists, medical physicists, dosimetrists, nurses, and radiation therapists.

摘要

目的

本实践参数由美国放射学会(ACR)和美国镭学会(ARS)合作修订。本实践参数提供了关于基于临床的常规全身照射和不断发展的容积调强全身照射的最新参考文献。

方法

本实践参数根据 ACR 网站上“开发 ACR 实践参数和技术标准的过程”标题下描述的过程(https://www.acr.org/Clinical-Resources/Practice-Parameters-and-Technical-Standards)由 ACR 放射肿瘤学实践参数委员会与 ARS 合作开发。

结果

本实践参数全面更新了关于常规全身照射和调强全身照射的参考文献。剂量率的依赖性仍然是常规设置(瞬时剂量率可以变化)和更现代的旋转技术中正在进行研究的活跃领域,在这些技术中,平均剂量率是相关变量。在患者设置过程中进行成像的作用以及基于计算机的治疗计划系统引起的不均匀性校正作为与整体剂量不均匀性密切相关的临床关注的新兴领域包括在内。人们越来越强调评估平均肺剂量的重要性,因为它与高剂量全身照射方案期间的毒性有关。

结论

本实践参数可作为设计和评估全身照射计划的有效工具,该计划成功地整合了放射肿瘤学家、医学物理学家、剂量师、护士和放射治疗师之间的密切互动和协调。