This article presents the outdoor and synthetic performance data concerning the main electrical parameters estimated from the I-V curve for three photovoltaic technologies (HIT, m-Si and CIGS) and the weather conditions (irradiance, ambient and panel temperature). Synthetic data were generated by simulating in OpenModelica software the impact of weather conditions on device performance, considering an irradiance range between 50 and 1300 W/m. The outdoor data corresponds to the performance of the evaluated PV modules in outdoor tests in Medellin-Colombia for ten months using capacitive I-V tracers. In both cases, different capacitor values were considered to evaluate the effect on the I-V curve behavior of devices.
本文展示了三种光伏技术(异质结背接触太阳能电池、单晶硅和铜铟镓硒)基于电流-电压(I-V)曲线估算的主要电气参数的室外及综合性能数据,以及天气条件(辐照度、环境温度和面板温度)。综合数据是通过在OpenModelica软件中模拟天气条件对器件性能的影响生成的,考虑的辐照度范围为50至1300瓦/平方米。室外数据对应于在哥伦比亚麦德林进行的为期十个月的室外测试中,使用电容式I-V跟踪仪对评估的光伏模块的性能。在这两种情况下,均考虑了不同的电容值,以评估其对器件I-V曲线行为的影响。