Suppr超能文献

神经退行性疾病中光学相干断层扫描血管造影参数的会话内重复性

Intrasession Repeatability of OCT Angiography Parameters in Neurodegenerative Disease.

作者信息

Akrobetu Dennis Y, Robbins Cason B, Ma Justin P, Soundararajan Srinath, Quist Michael S, Stinnett Sandra S, Moore Kathryn P L, Johnson Kim G, Liu Andy J, Grewal Dilraj S, Fekrat Sharon

机构信息

iMIND Research Group, Duke University School of Medicine, Durham, North Carolina.

Department of Ophthalmology, Duke University School of Medicine, Durham, North Carolina.

出版信息

Ophthalmol Sci. 2023 Jan 31;3(2):100275. doi: 10.1016/j.xops.2023.100275. eCollection 2023 Jun.

Abstract

PURPOSE

To assess the intrasession repeatability of macular OCT angiography (OCTA) parameters in Alzheimer's disease (AD), mild cognitive impairment (MCI), Parkinson's disease (PD), and normal cognition (NC).

DESIGN

Cross sectional study.

SUBJECTS

Patients with a clinical diagnosis of AD, PD, MCI, or NC were imaged. Images with poor quality and of those with diabetes mellitus, glaucoma, or vitreoretinal disease were excluded from analysis.

METHODS INTERVENTION OR TESTING

All participants were imaged using the Zeiss Cirrus HD-5000 with AngioPlex (Carl Zeiss Meditec, Software Version 11.0.0.29946) and repeat OCTA images were obtained for both eyes. Perfusion density (PFD), vessel density (VD), and Foveal avascular zone (FAZ) area were measured from 3 × 3 mm and 6 × 6 mm OCTA images centered on the fovea using an ETDRS grid overlay.

MAIN OUTCOME MEASURES

Intraclass correlation coefficients were used to quantify repeatability of PFD, VD, and FAZ area measurements obtained from imaging.

RESULTS

3 × 3 mm scans of 22 AD, 40 MCI, 21 PD, and 26 NC participants and 6 × 6 mm scans of 29 AD, 44 MCI, 29 PD, and 30 NC participants were analyzed. Repeatability values ranged from 0.64 (0.49-0.82) for 6 × 6 mm PFD in AD participants to 0.87 (0.67-0.92) for 3 × 3 mm PFD in AD participants. No significant differences were observed in repeatability between NC participants and those with neurodegenerative disease.

CONCLUSIONS

Overall, similar OCTA repeatability was observed between NC participants and those with neurodegeneration. Regardless of diagnostic group, macular OCTA metrics demonstrated moderate to good repeatability.

FINANCIAL DISCLOSURES

The authors have no proprietary or commercial interest in any materials discussed in this article.

摘要

目的

评估阿尔茨海默病(AD)、轻度认知障碍(MCI)、帕金森病(PD)和正常认知(NC)患者黄斑光学相干断层扫描血管造影(OCTA)参数的日内重复性。

设计

横断面研究。

研究对象

对临床诊断为AD、PD、MCI或NC的患者进行成像。将质量差以及患有糖尿病、青光眼或玻璃体视网膜疾病患者的图像排除在分析之外。

方法干预或测试

所有参与者均使用带有AngioPlex的蔡司Cirrus HD-5000(卡尔蔡司医疗技术公司,软件版本11.0.0.29946)进行成像,并对双眼获取重复的OCTA图像。使用ETDRS网格叠加,从以黄斑为中心的3×3mm和6×6mm OCTA图像中测量灌注密度(PFD)、血管密度(VD)和黄斑无血管区(FAZ)面积。

主要观察指标

组内相关系数用于量化成像获得的PFD、VD和FAZ面积测量的重复性。

结果

分析了22例AD、40例MCI、21例PD和26例NC参与者的3×3mm扫描图像,以及29例AD、44例MCI、29例PD和30例NC参与者的6×6mm扫描图像。重复性值范围从AD参与者6×6mm PFD的0.64(0.49 - 0.82)到AD参与者3×3mm PFD的0.87(0.67 - 0.92)。NC参与者与神经退行性疾病患者之间的重复性未观察到显著差异。

结论

总体而言,NC参与者与神经退行性疾病患者之间观察到相似的OCTA重复性。无论诊断组如何,黄斑OCTA指标均显示出中度至良好的重复性。

财务披露

作者对本文讨论的任何材料均无专有或商业利益。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba7b/10025280/964ee2e40592/gr1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验