Robbins Cason B, Grewal Dilraj S, Thompson Atalie C, Yoon Stephen P, Plassman Brenda L, Fekrat Sharon
Department of Ophthalmology, Duke University School of Medicine, Durham, NC, USA.
Department of Psychiatry and Behavioral Sciences, Duke University Medical Center, Durham, NC, USA.
J Vitreoretin Dis. 2020 Oct 1;5(3):239-246. doi: 10.1177/2474126420953968. eCollection 2021 May-Jun.
This work assesses the intrasession repeatability of capillary perfusion density (CPD) and capillary flux index (CFI) measurements on peripapillary optical coherence tomography angiography (OCTA) in healthy eyes of older adults.
In this cross-sectional study, healthy volunteers aged 50 years or older underwent 4.5 × 4.5 mm OCTA imaging centered on the optic nerve head using Zeiss Cirrus HD-5000 AngioPlex (Carl Zeiss Meditec). Two consecutive images were acquired in the same eye during a single study session. CPD and CFI were assessed using AngioPlex Software (version 11.0.0.29946) for the radial peripapillary capillary plexus (average over whole scan area) and 4 quadrants (superior, inferior, temporal, and nasal). CPD and CFI repeatability was assessed by intraclass correlation (ICC), mean interocular differences using 2-tailed test, and association with age using generalized estimating equations.
A total of 150 images were acquired from 75 eyes of 47 patients. For CPD, ICC results ranged from 0.7160 (nasal CPD) to 0.9218 (average CPD). For CFI, ICC results ranged from 0.6167 (temporal CFI) to 0.8976 (inferior CFI). Temporal CFI was significantly different between right and left eyes of the same patient ( = .03). CPD and CFI decreased with age in all analyses (average CPD β coefficient -0.00172, < .001; average CFI β coefficient -0.00278, < .001).
Moderate to good repeatability was observed for most peripapillary OCTA metrics; temporal measurements were least repeatable for CPD and CFI. Peripapillary CPD and CFI decrease with age even beyond the fifth decade in healthy older adults.
本研究评估在老年人健康眼中,基于视乳头周围光学相干断层扫描血管造影(OCTA)测量的毛细血管灌注密度(CPD)和毛细血管通量指数(CFI)在同一检查 session 内的可重复性。
在这项横断面研究中,50 岁及以上的健康志愿者使用蔡司 Cirrus HD - 5000 AngioPlex(卡尔蔡司医疗技术公司)对视神经乳头进行以其为中心的 4.5×4.5 毫米 OCTA 成像。在单个研究 session 期间,对同一只眼睛连续采集两张图像。使用 AngioPlex 软件(版本 11.0.0.29946)评估视乳头周围径向毛细血管丛(整个扫描区域的平均值)和四个象限(上、下、颞侧和鼻侧)的 CPD 和 CFI。通过组内相关系数(ICC)、使用双尾检验的平均眼间差异以及使用广义估计方程评估与年龄的关联来评估 CPD 和 CFI 的可重复性。
共从 47 名患者的 75 只眼中采集了 150 张图像。对于 CPD,ICC 结果范围从 0.7160(鼻侧 CPD)到 0.9218(平均 CPD)。对于 CFI,ICC 结果范围从 0.6167(颞侧 CFI)到 0.8976(下侧 CFI)。同一患者的右眼和左眼之间的颞侧 CFI 存在显著差异(P = 0.03)。在所有分析中,CPD 和 CFI 均随年龄下降(平均 CPD 的β系数为 -0.00172,P < 0.001;平均 CFI 的β系数为 -0.00278,P < 0.001)。
大多数视乳头周围 OCTA 指标具有中度到良好的可重复性;颞侧测量对于 CPD 和 CFI 的可重复性最差。在健康的老年人中,即使超过五十岁,视乳头周围的 CPD 和 CFI 也会随年龄下降。