Suppr超能文献

用于同时检测基质金属蛋白酶-1、基质金属蛋白酶-2和基质金属蛋白酶-9的有效伏安法工具;重要的非小细胞肺癌生物标志物。

Effective voltammetric tool for simultaneous detection of MMP-1, MMP-2, and MMP-9; important non-small cell lung cancer biomarkers.

作者信息

Kowalczyk Agata, Nisiewicz Monika K, Bamburowicz-Klimkowska Magdalena, Kasprzak Artur, Ruzycka-Ayoush Monika, Koszytkowska-Stawińska Mariola, Nowicka Anna M

机构信息

Faculty of Chemistry, University of Warsaw, Pasteura Str. 1, PL 02-093, Warsaw, Poland.

Faculty of Chemistry, University of Warsaw, Pasteura Str. 1, PL 02-093, Warsaw, Poland; Faculty of Chemistry, Warsaw University of Technology, Noakowskiego Str. 3, PL 00-664, Warsaw, Poland.

出版信息

Biosens Bioelectron. 2023 Jun 1;229:115212. doi: 10.1016/j.bios.2023.115212. Epub 2023 Mar 7.

Abstract

Simultaneous detection of multiple biomarkers can allow to reduce the costs of medical diagnostics, and thus improve the accuracy and effectiveness of disease diagnosis and prognosis. Here, for the first time, we present a low-cost, simple, and rapid method for simultaneous detection of three matrix metalloproteinases (MMP-1, MMP-2, and MMP-9) that play important roles in the progression of lung cancer. The sensor matrix was constructed using a G2 polyamidoamine dendrimer (PAMAM) containing amino, carboxyl, and sulfhydryl groups. The recognition process was based on specific enzymatic cleavage of the Gly-Ile peptide bond by MMP-1, Gly-Leu bond by MMP-2, and Gly-Met bond by MMP-9, and monitoring was done by square wave voltammetry. The activity of metalloproteinases was detected based on the change of current signals of redox receptors (dipeptides labeled with electroactive compounds) covalently anchored onto the electrode surface. The conditions of the biosensor construction, including the concentration of receptors on the sensor surface and the time of interaction of the receptor with the analyte, were carefully optimized. Under optimal conditions, the linear response of the developed method ranged from 1.0⋅10 to 1.0 mg⋅L, and the limit of detection for MMP-1, MMP-2, and MMP-9 was 0.35, 0.62, and 1.10 fg⋅mL, respectively. The constructed biosensor enabled us to efficiently profile the levels of active forms of MMP-1, MMP-2, and MMP-9 in tissue samples (plasma and lung and tumor extracts). Thus, the developed biosensor can aid in the early detection and diagnosis of lung cancer.

摘要

同时检测多种生物标志物可以降低医学诊断成本,从而提高疾病诊断和预后的准确性与有效性。在此,我们首次提出一种低成本、简单且快速的方法,用于同时检测在肺癌进展中起重要作用的三种基质金属蛋白酶(MMP - 1、MMP - 2和MMP - 9)。传感器基质是使用含有氨基、羧基和巯基的G2聚酰胺胺树枝状大分子(PAMAM)构建的。识别过程基于MMP - 1对Gly - Ile肽键、MMP - 2对Gly - Leu肽键以及MMP - 9对Gly - Met肽键的特异性酶切作用,并通过方波伏安法进行监测。基于共价锚定在电极表面的氧化还原受体(标记有电活性化合物的二肽)电流信号的变化来检测金属蛋白酶的活性。对生物传感器构建条件进行了仔细优化,包括传感器表面受体的浓度以及受体与分析物的相互作用时间。在最佳条件下,所开发方法的线性响应范围为1.0×10至1.0 mg·L,MMP - 1、MMP - 2和MMP - 9的检测限分别为0.35、0.62和1.10 fg·mL。构建的生物传感器使我们能够有效地分析组织样本(血浆、肺和肿瘤提取物)中MMP - 1、MMP - 2和MMP - 9活性形式的水平。因此,所开发的生物传感器有助于肺癌的早期检测和诊断。