Suppr超能文献

使用生物工程、细胞友好型、光滑表面装置对韩国女性进行基于植入物的隆乳术初步短期安全性结果的高分辨率超声辅助评估。

High-Resolution Ultrasound-Assisted Assessment of Preliminary Short-term Safety Outcomes of an Implant-Based Augmentation Mammaplasty Using a Bioengineered, Cell-Friendly, Smooth-Surface Device in Korean Females.

作者信息

Lee Sangdal, Jeong Jeong Pil, Sung Jung Youp, Choi Woo Sik, Moon Dong Seung, Kim Ho Chan, Kim Jae Hong

出版信息

Aesthet Surg J Open Forum. 2021 Nov 9;4:ojab046. doi: 10.1093/asjof/ojab046. eCollection 2022.

Abstract

BACKGROUND

The Motiva Ergonomix Round SilkSurface (Establishment Labs Holdings Inc., Alajuela, Costa Rica) is one of the representative brands of the fifth generation of a silicone gel-filled breast implant with a microtextured surface.

OBJECTIVES

In this study, the authors describe preliminary short-term safety outcomes of an implant-based augmentation mammaplasty using the Motiva Ergonomix Round SilkSurface in Korean females.

METHODS

The authors performed a retrospective analysis of medical records in a total of 69 females (n = 69) receiving an implant-based augmentation mammaplasty using the Motiva Ergonomix Round SilkSurface between September 26, 2017, and December 31, 2020. The authors analyzed incidences of postoperative complications.

RESULTS

A total of 6 cases (8.7%) of postoperative complications occurred; these include 2 cases (2.9%) of early seroma, 1 case (1.4%) of capsular contracture, 2 cases (2.9%) of alterations in the shape, and 1 case (1.4%) of foreign body sensation. Time-to-events were estimated at 266.81 ± 273.17 days.

CONCLUSIONS

The authors describe our preliminary short-term safety outcomes of an implant-based augmentation mammaplasty using the Motiva Ergonomix Round SilkSurface in Korean females. But this deserves further large-scale studies with long periods of follow-up.

摘要

背景

Motiva Ergonomix圆形丝滑表面乳房植入物(Establishment Labs Holdings Inc.,阿拉胡埃拉,哥斯达黎加)是第五代带有微纹理表面的硅胶填充乳房植入物的代表品牌之一。

目的

在本研究中,作者描述了在韩国女性中使用Motiva Ergonomix圆形丝滑表面乳房植入物进行隆乳术的初步短期安全性结果。

方法

作者对2017年9月26日至2020年12月31日期间共69名接受Motiva Ergonomix圆形丝滑表面乳房植入物隆乳术的女性的病历进行了回顾性分析。作者分析了术后并发症的发生率。

结果

共发生6例(8.7%)术后并发症;其中包括2例(2.9%)早期血清肿、1例(1.4%)包膜挛缩、2例(2.9%)外形改变和1例(1.4%)异物感。事件发生时间估计为266.81±273.17天。

结论

作者描述了在韩国女性中使用Motiva Ergonomix圆形丝滑表面乳房植入物进行隆乳术的初步短期安全性结果。但这值得进一步进行长期的大规模研究。