Abstract

BACKGROUND

A point-of-care ultrasound (POCUS) protocol for evaluation of the cardiac and respiratory systems in horses does not exist.

OBJECTIVES

(a) Describe the windows of a POCUS protocol for cardiorespiratory assessment of horses (CRASH); (b) Estimate the number of acoustic windows that can be acquired by a sonographer-in-training; (c) Estimate the time required to complete the protocol for specific groups of horses; (d) Describe the sonographic abnormalities detected in horses presented with cardiovascular, respiratory, or systemic disease.

ANIMALS

Twenty-seven healthy horses, 14 horses competing in athletic events, and 120 horses with clinical disease.

METHOD

A pocket-sized ultrasound device was used to acquire 7 sonographic cardiorespiratory windows in various clinical scenarios. The duration of the examination was timed, and images were evaluated for diagnostic quality. Abnormalities in horses with clinical disease were determined by an expert sonographer.

RESULTS

The CRASH protocol could be performed in healthy and diseased horses in hospital, barn, and competition settings between 5.5 ± 0.9 (athletic horses) and 6.9 ± 1.9 min (horses with clinical disease). Thoracic windows were obtained most consistently, followed by right parasternal long-axis echocardiographic windows. Frequently detected abnormalities were pleural fluid, lung consolidation, B-lines, and moderate-to-severe left-sided heart disease.

CONCLUSIONS

The CRASH protocol was feasible using a pocket-sized ultrasound device in various groups of horses, could be completed rapidly in a variety of settings, and frequently identified sonographic abnormalities when evaluated by an expert sonographer. The diagnostic accuracy, observer agreement, and utility of the CRASH protocol merit further evaluation.

摘要

背景

目前尚无针对马的心肺系统的即时超声(POCUS)检查协议。

目的

(a)描述用于马心肺评估的即时超声检查协议(CRASH)的声窗;(b)估计经过培训的超声技师能够获得的声窗数量;(c)估计特定组别的马完成该方案所需的时间;(d)描述在心血管、呼吸或全身性疾病马中发现的超声异常。

动物

27 匹健康马、14 匹竞技马和 120 匹患有临床疾病的马。

方法

使用便携式超声设备在各种临床情况下获取 7 个超声心肺声窗。记录检查时间,并评估图像的诊断质量。由专家超声技师确定患有临床疾病的马的超声异常。

结果

CRASH 方案可在医院、马厩和比赛环境中对健康和患病的马进行检查,竞技马的检查时间为 5.5±0.9 分钟,临床疾病马的检查时间为 6.9±1.9 分钟。最常获得的声窗是胸腔声窗,其次是右胸骨旁长轴超声心动图声窗。经常发现的异常包括胸腔积液、肺实变、B 线和中重度左侧心脏疾病。

结论

使用便携式超声设备,CRASH 方案可在各种马群中实施,在各种环境中可快速完成,且由专家超声技师评估时可频繁识别出超声异常。CRASH 方案的诊断准确性、观察者间一致性和实用性值得进一步评估。