Hroncekova Stefania, Lorencova Lenka, Bertok Tomas, Hires Michal, Jane Eduard, Bučko Marek, Kasak Peter, Tkac Jan
Institute of Chemistry, Slovak Academy of Sciences, Dubravska Cesta 9, 845 38 Bratislava, Slovakia.
Center for Advanced Materials, Qatar University, Doha P.O. Box 2713, Qatar.
J Funct Biomater. 2023 Mar 17;14(3):161. doi: 10.3390/jfb14030161.
Screen-printing technology is a game changer in many fields including electrochemical biosensing. Two-dimensional nanomaterial MXene TiCT was integrated as a nanoplatform to immobilise enzyme sarcosine oxidase (SOx) onto the interface of screen-printed carbon electrodes (SPCEs). A miniaturised, portable, and cost-effective nanobiosensor was constructed using chitosan as a biocompatible glue for the ultrasensitive detection of prostate cancer biomarker sarcosine. The fabricated device was characterised with energy-dispersive X-ray spectroscopy (EDX), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). Sarcosine was detected indirectly via the amperometric detection of HO formed during enzymatic reaction. The nanobiosensor could detect sarcosine down to 7.0 nM with a maximal peak current output at 4.10 ± 0.35 × 10 A using only 100 µL of a sample per measurement. The assay run in 100 μL of an electrolyte showed the first linear calibration curve in a concentration window of up to 5 μM with a slope of 2.86 μA·μM, and the second linear calibration curve in the range of 5-50 μM with a slope of 0.32 ± 0.01 μA·μM (R = 0.992). The device provided a high recovery index of 92.5% when measuring an analyte spiked into artificial urine, and could be used for detection of sarcosine in urine for at least a period of 5 weeks after the preparation.
丝网印刷技术在包括电化学生物传感在内的许多领域都是一项变革性技术。二维纳米材料MXene TiCT被整合为一种纳米平台,用于将肌氨酸氧化酶(SOx)固定在丝网印刷碳电极(SPCEs)的界面上。使用壳聚糖作为生物相容性胶水构建了一种小型化、便携式且经济高效的纳米生物传感器,用于超灵敏检测前列腺癌生物标志物肌氨酸。所制备的器件通过能量色散X射线光谱(EDX)、电化学阻抗谱(EIS)和循环伏安法(CV)进行表征。通过对酶促反应过程中形成的HO进行安培检测间接检测肌氨酸。该纳米生物传感器每次测量仅使用100 μL样品,就能检测低至7.0 nM的肌氨酸,最大峰值电流输出为4.10 ± 0.35 × 10 A。在100 μL电解质中进行的测定显示,在高达5 μM的浓度窗口内有第一条线性校准曲线,斜率为2.86 μA·μM,在5 - 50 μM范围内有第二条线性校准曲线,斜率为0.32 ± 0.01 μA·μM(R = 0.992)。该器件在测量添加到人工尿液中的分析物时提供了92.5%的高回收率指数,并且在制备后至少5周内可用于检测尿液中的肌氨酸。