Suppr超能文献

评估多发性硬化症中视神经直径的经眶超声测量值与全脑和局部脑容量的关系。

Evaluation of transorbital sonography measures of optic nerve diameter in the context of global and regional brain volume in multiple sclerosis.

机构信息

Department of Radiology, Albert Szent-Györgyi Clinical Center, University of Szeged, Szeged, Hungary.

Department of Psychiatry, Albert Szent-Györgyi Clinical Center, University of Szeged, Szeged, Hungary.

出版信息

Sci Rep. 2023 Apr 5;13(1):5578. doi: 10.1038/s41598-023-31706-5.

Abstract

Transorbital sonography (TOS) could be a swift and convenient method to detect the atrophy of the optic nerve, possibly providing a marker that might reflect other quantitative structural markers of multiple sclerosis (MS). Here we evaluate the utility of TOS as a complementary tool for assessing optic nerve atrophy, and investigate how TOS-derived measures correspond to volumetric brain markers in MS. We recruited 25 healthy controls (HC) and 45 patients with relapsing-remitting MS and performed B-mode ultrasonographic examination of the optic nerve. Patients additionally underwent MRI scans to obtain T1-weighted, FLAIR and STIR images. Optic nerve diameters (OND) were compared between HC, MS patients with and without history of optic neuritis (non-ON) using a mixed-effects ANOVA model. The relationship between within-subject-average OND and global and regional brain volumetric measures was investigated using FSL SIENAX, voxel-based morphometry and FSL FIRST. OND was significantly different between HC-MS (HC = 3.2 ± 0.4 mm, MS = 3 ± 0.4 mm; p < 0.019) and we found significant correlation between average OND and normalised whole brain (β = 0.42, p < 0.005), grey matter (β = 0.33, p < 0.035), white matter (β = 0.38, p < 0.012) and ventricular cerebrospinal fluid volume (β = - 0.36, p < 0.021) in the MS group. History of ON had no impact on the association between OND and volumetric data. In conclusion, OND is a promising surrogate marker in MS, that can be simply and reliably measured using TOS, and its derived measures correspond to brain volumetric measures. It should be further explored in larger and longitudinal studies.

摘要

经眶超声(TOS)可能是一种快速便捷的检测视神经萎缩的方法,它可能提供一个标志物,反映多发性硬化症(MS)的其他定量结构标志物。在此,我们评估 TOS 作为评估视神经萎缩的辅助工具的效用,并研究 TOS 衍生的测量值与 MS 中脑容积标志物的相关性。我们招募了 25 名健康对照者(HC)和 45 名复发缓解型 MS 患者,并对其视神经进行 B 型超声检查。患者还进行了 MRI 扫描,以获得 T1 加权、FLAIR 和 STIR 图像。使用混合效应方差分析模型比较 HC、有和无视神经炎病史的 MS 患者(非 ON)之间的视神经直径(OND)。使用 FSL SIENAX、基于体素的形态测量法和 FSL FIRST 研究了个体内平均 OND 与全脑和区域脑容积测量值之间的关系。HC-MS 之间的 OND 差异显著(HC=3.2±0.4mm,MS=3±0.4mm;p<0.019),我们发现平均 OND 与正常化全脑(β=0.42,p<0.005)、灰质(β=0.33,p<0.035)、白质(β=0.38,p<0.012)和脑室脑脊液体积(β=-0.36,p<0.021)之间存在显著相关性。ON 病史对 OND 与容积数据之间的相关性没有影响。总之,OND 是 MS 中很有前途的替代标志物,可通过 TOS 简单可靠地测量,其衍生的测量值与脑容积测量值相对应。应该在更大和纵向研究中进一步探索。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0852/10076391/d86d55fa03dd/41598_2023_31706_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验