Suppr超能文献

四原则:一种基于解剖学和价值的用于治疗钝性胸主动脉损伤的覆膜支架库存管理方法。

Rule of four: an anatomic and value-based approach to stent-graft inventory for blunt thoracic aortic injury.

机构信息

Department of Surgery and Perioperative Care, Dell Medical School, University of Texas at Austin, 1500 Red River Street, Annex, Austin, TX, 78701, USA.

R Adams Cowley Shock Trauma Center, University of Maryland, Baltimore, MD, USA.

出版信息

Eur J Trauma Emerg Surg. 2023 Oct;49(5):2173-2176. doi: 10.1007/s00068-023-02267-z. Epub 2023 Apr 8.

Abstract

PURPOSE

As blunt thoracic aortic injury (BTAI) treatment has shifted from open to thoracic endovascular aortic repair (TEVAR), logistical challenges exist in creating and maintaining inventories of appropriately sized stent-grafts, including storage demands, shelf-life management and cost. We hypothesized that most injured aortas can be successfully repaired with a narrow range of stent-graft sizes and present a value-based anatomic approach to optimizing inventory.

METHODS

CT-scans of all patients with BTAI admitted to our Level I trauma center from Apr 2010-Dec 2018 were reviewed. Patients with anatomy incompatible with TEVAR were excluded. For each patient, after aortic sizing a set of two stent-grafts most likely to be utilized was selected from a list of twenty commercially available GORE conformable TAG endografts based on manufacturer instructions. Stent-graft sizes were then ranked based on the number of cases they would be suitable for. MATLAB was utilized to determine the combinations of stent-grafts which would cover the most patients.

RESULTS

Twenty-eight patients with BTAI were identified and three were excluded based on iliac diameter. Most patients were male (68%), mean age 42.3 ± 20.2 years, mean ISS 37.0 ± 9.8. Overall mortality was 25%. Of the 20 available stent-graft options, a combination of four stent-grafts would successfully treat 100% of the patients in this series.

CONCLUSIONS

Based on actual CT-scan aortic measurements, we demonstrated that an inventory of four sent-graft sizes was sufficient to treat 100% of patients with BTAI. These data can be utilized as a value-based anatomic approach to aortic stent-graft institutional inventory creation and maintenance.

摘要

目的

随着胸主动脉钝性损伤(BTAI)的治疗从开放性手术转向胸主动脉腔内修复术(TEVAR),在创建和维持适当尺寸支架移植物库存方面存在后勤挑战,包括存储需求、保质期管理和成本。我们假设大多数受伤的主动脉可以用较窄范围的支架移植物尺寸成功修复,并提出一种基于价值的解剖方法来优化库存。

方法

回顾 2010 年 4 月至 2018 年 12 月期间我院收治的所有 BTAI 患者的 CT 扫描。排除与 TEVAR 不兼容的解剖结构的患者。对于每个患者,在主动脉测量后,根据制造商的说明,从二十种市售戈尔顺应性 TAG 腔内移植物中选择一套两种最有可能使用的支架移植物。然后根据适合的病例数量对支架移植物的尺寸进行排名。使用 MATLAB 确定可覆盖最多患者的支架移植物组合。

结果

确定了 28 例 BTAI 患者,有 3 例因髂动脉直径而被排除。大多数患者为男性(68%),平均年龄 42.3±20.2 岁,ISS 平均为 37.0±9.8。总体死亡率为 25%。在 20 种可用的支架移植物选择中,四种支架移植物的组合可以成功治疗本系列中的 100%患者。

结论

根据实际 CT 扫描的主动脉测量结果,我们证明了四种支架移植物的库存足以治疗 100%的 BTAI 患者。这些数据可作为基于价值的解剖方法用于创建和维护主动脉支架移植物机构库存。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验