Suppr超能文献

基于临床指征的CT剂量。冰岛新的国家剂量参考水平。

CT doses based on clinical indications. New national DRL's in Iceland.

作者信息

Guðjónsdóttir Jónína, Michelsen Sigurbjörg Sigurðard, Björnsdóttir Guðlaug, Guðmundsdóttir Valdís Klara

机构信息

Icelandic Radiation Safety Authority. Rauðarárstígur 10, 105 Reykjavík, Iceland; University of Iceland, Faculty of Medicine. Vatnsmýrarvegur 16, 101 Reykjavík, Iceland.

University of Iceland, Faculty of Medicine. Vatnsmýrarvegur 16, 101 Reykjavík, Iceland; Icelandic Heart Association. Holtasmári 1, 201 Kópavogur, Iceland.

出版信息

Phys Med. 2023 May;109:102576. doi: 10.1016/j.ejmp.2023.102576. Epub 2023 Apr 11.

Abstract

A diagnostic reference level (DRL) is an investigation level to use in the optimization of a medical exposure using ionizing radiation. The aim of this project was to gather dose data from computed tomography (CT) studies in Iceland with the purpose of updating existing national DRL and proposing DRLs based on clinical indications. Dose data (total dose length product (DLP) and CT dose index) were retrospectively collected from all CT scanners in Iceland for 50 patients for all common CT studies. After cleaning the data, the data set contained total DLP for 8129 patients. Considering dose-relevant parameters such as the number of phases and scan length, each CT study was assigned to one of 42 study types and (at least) one clinical indication. Data were received from seven or more scanners for 13 clinical indications and from all scanners providing coronary angiography. There was considerable variation in the median total DLP from different scanners, e.g., from 13 to 139 mGycm for Sinusitis, and, the range of individual total DLPs varied between scanners. This underscores the importance of monitoring patients' exposure. The study shows that there is room for optimization. New Icelandic NDRLs were proposed for the total DLP of CT examinations based on ten different indications, including: Brain ischemia (1060 mGycm), Interstitial lung disease (310 mGycm) and Appendicitis (690 mGycm). The proposed NDRLs were the first clinical indication based NDRLs in Iceland. The Icelandic Radiation Safety Authority has decided to update the NDRLs based on the results of this study.

摘要

诊断参考水平(DRL)是在优化使用电离辐射的医学照射时所采用的一种照射水平。本项目的目的是收集冰岛计算机断层扫描(CT)研究的剂量数据,以便更新现有的国家DRL,并根据临床指征提出DRL。回顾性收集了冰岛所有CT扫描仪针对50名患者进行的所有常见CT研究的剂量数据(总剂量长度乘积(DLP)和CT剂量指数)。在清理数据后,数据集包含了8129名患者的总DLP。考虑到与剂量相关的参数,如相数和扫描长度,每项CT研究被归类为42种研究类型之一以及(至少)一种临床指征。针对13种临床指征,从7台或更多台扫描仪收集到了数据,对于提供冠状动脉造影的所有扫描仪也都收集到了数据。不同扫描仪的总DLP中位数存在相当大的差异,例如,鼻窦炎的中位数总DLP在13至139 mGycm之间,而且,不同扫描仪之间个体总DLP的范围也有所不同。这凸显了监测患者照射剂量的重要性。该研究表明仍有优化空间。基于包括脑缺血(1060 mGycm)、间质性肺疾病(310 mGycm)和阑尾炎(690 mGycm)在内的十种不同指征,提出了冰岛CT检查总DLP的新国家DRL。所提出的国家DRL是冰岛首个基于临床指征的国家DRL。冰岛辐射安全管理局已决定根据本研究结果更新国家DRL。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验