This study reports on the safety and efficacy of Xen 45 in patients with glaucoma and high myopia. It was a retrospective study including patients with high myopia (>6D) who underwent Xen implant with 2 years of follow-up. The primary outcome was to report the incidence of hypotony (IOP ≤ 5 mmHg) and hypotony-related complications. Patients with high myopia treated with mitomycin-C-augmented trabeculectomy were included as a control group. We included 14 consecutive patients who underwent Xen implant (seven eyes) and trabeculectomy (seven eyes). The mean myopia was -14.71 ± 5.36 and -15.07 ± 6.11 in the trabeculectomy and Xen groups, respectively ( > 0.05). The success rate and the mean IOP at 1 and 2 years from the intervention were statistically comparable between the two groups. The group undergoing trabeculectomy showed a higher incidence of hypotony (six eyes (85.71%) vs. two eyes (28.57%)) and hypotony maculopathy (three eyes (42.86%) vs. zero eyes (0%)) and required more postoperative procedures. Patients with high myopia were at higher risk of hypotony-related complications after trabeculectomy. The Xen implant can achieve an IOP control comparable to trabeculectomy with a significantly better safety profile and can be considered as an option for the management of patients with high myopia and glaucoma.

摘要

本研究报告了Xen 45在青光眼和高度近视患者中的安全性和有效性。这是一项回顾性研究,纳入了接受Xen植入且随访2年的高度近视(>6D)患者。主要结局是报告低眼压(眼压≤5 mmHg)及低眼压相关并发症的发生率。接受丝裂霉素C辅助小梁切除术治疗的高度近视患者作为对照组。我们纳入了14例连续接受Xen植入术(7只眼)和小梁切除术(7只眼)的患者。小梁切除术组和Xen植入术组的平均近视度数分别为-14.71±5.36和-15.07±6.11(>0.05)。两组干预后1年和2年的成功率及平均眼压在统计学上具有可比性。小梁切除术组的低眼压发生率更高(6只眼(85.71%) vs. 2只眼(28.57%)),低眼压性黄斑病变发生率也更高(3只眼(42.86%) vs. 0只眼(0%)),且术后需要更多的治疗措施。高度近视患者小梁切除术后发生低眼压相关并发症的风险更高。Xen植入术在眼压控制方面可达到与小梁切除术相当的效果,且安全性显著更好,可被视为高度近视合并青光眼患者的一种治疗选择。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/fa8c/10095138/63fd75958a26/jcm-12-02477-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验