Suppr超能文献

一种通用粘合剂的剪切粘结强度和氟释放:对乳牙的体外研究

Shear Bond Strength and Fluoride Release of a Universal Adhesive: An In-Vitro Study on Primary Teeth.

作者信息

Alsaadawi Alaa, Felemban Osama, Nassar Hani M, Abdelbaki Medhat

机构信息

Department of Pediatric Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia.

Department of Restorative Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia.

出版信息

Materials (Basel). 2023 Mar 23;16(7):2573. doi: 10.3390/ma16072573.

Abstract

This investigation aimed to assess the shear bond strength and fluoride-releasing capabilities of Clearfil Universal Bond Quick (Kuraray Noritake Dental Inc., Tokyo, Japan). Forty-four extracted primary molars were divided into two groups, and the enamel substrate was prepared for evaluating shear bond strength. Scotchbond (3M ESPE) and Clearfil UBQ were used to bond composite-to-enamel substrates in each group ( = 22). Shear bond strength was measured using a universal testing device and compared. Sixteen discs (6 mm diameter and 3 mm thickness) were fabricated from each Clearfil UBQ, Fuji IX, and Fuji II LC. Over the course of 30 days, each materials' fluoride release was examined and compared using ion analysis. Results revealed that Clearfil UBQ had statistically similar shear bond strength to Scotchbond. Between the three materials, Clearfil UBQ had the lowest fluoride release at baseline (0.11 ± 0.25) and the lowest cumulative fluoride release (0.12-0.27 ppm) over 30 days. Fuji IX had the highest fluoride release at baseline (19.38 ± 2.50) and cumulatively (40.87 ± 4.03 ppm), followed by Fuji II LC. We conclude that Clearfil UBQ and Scotchbond showed comparable bond strengths to the enamel. Fluoride release was seen in Clearfil UBQ in the initial two days of the 30-day period. The amount of fluoride release was significantly less than with glass ionomer cements.

摘要

本研究旨在评估Clearfil Universal Bond Quick(日本东京可乐丽诺瑞特牙科公司)的剪切粘结强度和氟释放能力。44颗拔除的乳磨牙被分为两组,并制备牙釉质基底以评估剪切粘结强度。每组使用Scotchbond(3M ESPE)和Clearfil UBQ将复合材料粘结到牙釉质基底上(每组n = 22)。使用万能测试装置测量并比较剪切粘结强度。从每种Clearfil UBQ、Fuji IX和Fuji II LC制作16个圆盘(直径6 mm,厚度3 mm)。在30天的时间里,使用离子分析检查并比较每种材料的氟释放情况。结果显示,Clearfil UBQ的剪切粘结强度在统计学上与Scotchbond相似。在这三种材料中,Clearfil UBQ在基线时的氟释放量最低(0.11±0.25),在30天内的累积氟释放量也最低(0.12 - 0.27 ppm)。Fuji IX在基线时(19.38±2.50)和累积时(40.87±4.03 ppm)的氟释放量最高,其次是Fuji II LC。我们得出结论,Clearfil UBQ和Scotchbond对牙釉质的粘结强度相当。在30天周期的前两天,Clearfil UBQ出现了氟释放。氟释放量明显低于玻璃离子水门汀。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9417/10095296/167f438634f4/materials-16-02573-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验