Suppr超能文献

可重复使用的柔性支气管镜的交叉污染率:一项系统文献综述和荟萃分析。

Cross-contamination rate of reusable flexible bronchoscopes: A systematic literature review and meta-analysis.

作者信息

Travis Helena S, Russell Rasmus V, Kovaleva Julia

机构信息

Ambu A/S, Ballerup, Denmark.

Clinical Microbiologist/Clinical Pathologist, Labo Nuytinck-Anacura, Evergem, Belgium.

出版信息

J Infect Prev. 2023 May;24(3):95-102. doi: 10.1177/17571774231158203. Epub 2023 Feb 24.

Abstract

BACKGROUND

Bronchoscopy is generally a safe and efficient procedure. However, the risk of cross-contamination with reusable flexible bronchoscopes (RFB) has been detected in several outbreaks worldwide.

AIM

To estimate the average cross-contamination rate of patient-ready RFBs based on available published data.

METHODS

We performed a systematic literature review in PubMed and Embase to investigate the cross-contamination rate of RFB. Included studies identified indicator organisms or colony forming units (CFU) levels, and total number of samples >10. The Contamination threshold was defined according to the European Society of Gastrointestinal Endoscopy and European Society of Gastrointestinal Endoscopy Nurse and Associates (ESGE-ESGENA) guidelines. To calculate the total contamination rate, a random effects model was applied. Heterogeneity was analysed via a Q-test and illustrated in a forest plot. Publication bias was analysed via the Egger's regression test and illustrated in a funnel plot.

RESULTS

Eight studies fulfilled our inclusion criteria. The random effects model included 2169 samples and 149 events (positive tests). The total RFB cross-contamination rate was 8.69% ± 1.86 (standard division [SD]) (95% confidence interval [CI]: 5.06-12.33%). The result showed significant heterogeneity of 90% and publication bias.

DISCUSSION

Significant heterogeneity and publication bias is likely associated with varying methodology and aversion towards publishing negative findings, respectively. Based on the cross-contamination rate an infection control paradigm shift is needed to ensure patient safety. We recommend to follow the Spaulding classification and classify RFBs as critical items. Accordingly, infection control measures such as obligatory surveillance, and implementing single-use alternatives must be considered where feasible.

摘要

背景

支气管镜检查通常是一种安全有效的操作。然而,在全球多起疫情中已检测到可重复使用的柔性支气管镜(RFB)存在交叉污染风险。

目的

根据现有已发表数据估算准备好用于患者的RFB的平均交叉污染率。

方法

我们在PubMed和Embase上进行了系统的文献综述,以调查RFB的交叉污染率。纳入的研究确定了指示生物或菌落形成单位(CFU)水平,以及样本总数>10。污染阈值根据欧洲胃肠内镜学会和欧洲胃肠内镜护士及协会(ESGE-ESGENA)指南定义。为计算总污染率,应用了随机效应模型。通过Q检验分析异质性,并在森林图中显示。通过Egger回归检验分析发表偏倚,并在漏斗图中显示。

结果

八项研究符合我们的纳入标准。随机效应模型纳入了2169个样本和149个事件(阳性检测)。RFB的总交叉污染率为8.69%±1.86(标准差[SD])(95%置信区间[CI]:5.06 - 12.33%)。结果显示存在90%的显著异质性和发表偏倚。

讨论

显著的异质性和发表偏倚可能分别与方法的不同以及不愿发表阴性结果有关。基于交叉污染率,需要转变感染控制模式以确保患者安全。我们建议遵循斯波尔丁分类法,将RFB归类为关键物品。因此,在可行的情况下,必须考虑采取如强制性监测和实施一次性替代品等感染控制措施。