Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, Missouri.
Peachtree Orthopedics, Atlanta, Georgia.
J Arthroplasty. 2023 Jul;38(7 Suppl 2):S346-S350. doi: 10.1016/j.arth.2023.04.041. Epub 2023 Apr 25.
Highly cross-linked polyethylene (HXLPE) is a widely used bearing surface in total hip arthroplasty (THA); long-term results in young patients are limited. We previously demonstrated excellent results in HXPLE on cobalt-chrome femoral heads at 15-year mean follow-up. The purpose of the present study was to investigate polyethylene wear rates, implant survivorships, wear-related revisions, and patient-reported outcomes (PROs) in a young patient cohort who had alumina ceramic on HXPLE coupling at an average 16-year follow-up.
This was a retrospective study of 128 hips that underwent THA with HXLPE on alumina ceramic bearings between March 1, 2004, and April 15, 2007. The patient's mean age was 38 years (range, 13 to 50). All THAs utilized HXPLE liners with alumina ceramic heads. The University of California, Los Angeles activity score and modified Harris hip scores were collected preoperatively and at each follow-up. Martell hip analysis suite was used for wear calculations.
At average 16 years (range, 13 to 18), aseptic revision survivorship was 93.3% and osteolysis/wear survivorship was 99.2%. The mean linear wear rate was 0.0191 mm/year and mean volumetric wear rate was 19.43 mm/y, both of which were clinically undetectable. We observed excellent PROs with a significant increase in mean modified Harris hip scores (43.6 to 87.4, P < .0001) and the University of California, Los Angeles activity scores (4.0 to 6.0, P < .0001). There were no statistically significant differences in PROs or wear rates between ceramic and cobalt-chrome groups.
At a mean 16-year follow-up, young patients who had HXLPE on ceramic coupling had excellent wear properties, PROs, and acceptable survivorships.
高度交联聚乙烯(HXLPE)是全髋关节置换术(THA)中广泛使用的承载体;在年轻患者中的长期结果有限。我们之前在钴铬股骨头的 HXPLE 上进行了 15 年的平均随访,结果显示效果非常好。本研究的目的是在平均 16 年随访时,研究在 HXPLE 陶瓷结合的年轻患者中聚乙烯磨损率、植入物存活率、与磨损相关的翻修和患者报告的结果(PROs)。
这是一项回顾性研究,共纳入 128 例髋关节,于 2004 年 3 月 1 日至 2007 年 4 月 15 日期间接受 HXLPE 与氧化铝陶瓷轴承的 THA。患者的平均年龄为 38 岁(范围为 13 至 50 岁)。所有的 THA 都使用 HXPLE 衬垫和氧化铝陶瓷头。术前和每次随访时收集加利福尼亚大学洛杉矶分校活动评分和改良 Harris 髋关节评分。采用 Martell 髋关节分析套件进行磨损计算。
平均随访 16 年(范围为 13 至 18 年),无菌性翻修存活率为 93.3%,骨溶解/磨损存活率为 99.2%。平均线性磨损率为 0.0191mm/年,平均容积磨损率为 19.43mm/y,均为临床不可检测。我们观察到了优异的 PROs,改良 Harris 髋关节评分(43.6 至 87.4,P<.0001)和加利福尼亚大学洛杉矶分校活动评分(4.0 至 6.0,P<.0001)均有显著增加。陶瓷组和钴铬组之间的 PROs 和磨损率没有统计学差异。
在平均 16 年的随访中,接受陶瓷结合的 HXLPE 的年轻患者具有良好的磨损性能、PROs 和可接受的存活率。