Heat Generation During Initial Osteotomy for Implant Site Preparation: An In Vitro Measurement Study.

作者信息

Aquilanti Luca, Antognoli Luca, Rappelli Giorgio, Di Felice Roberto, Scalise Lorenzo

机构信息

Department of Clinical Specialistic and Dental Sciences, Università Politecnica Delle Marche, Ancona, Italy.

Department of Industrial Engineering and Mathematical Sciences, Università Politecnica Delle Marche, Ancona, Italy.

出版信息

J Maxillofac Oral Surg. 2023 Jun;22(2):313-320. doi: 10.1007/s12663-022-01800-8. Epub 2022 Oct 27.

Abstract

INTRODUCTION

Controlling temperature generation during implant site preparation is important to prevent implant early failure.

AIM

The present in vitro study aimed at measuring temperature variation generated during the initial osteotomy using both rotatory and piezo-surgical inserts.

METHODS

Nine groups were defined according to drill and insert type, cooling volume (mL/min) and cooling temperature. A total of 315 implant site preparations were performed in an artificial bone sample and the temperature was measured using an infrared camera. Drills' wear was assessed using scanning electron microscopy at baseline and after 10 and 35 utilizations.

RESULTS

Piezo-surgical insert groups determined a temperature increase that was significantly higher than the one generated by rotatory drills groups ( < 0.001). When considering rotatory drills groups a temperature ≥ 40 °C was never recorded.

CONCLUSION

Lower saline temperature implied a significant temperature decrease ( < 0.001), while the increase in cooling volume did not imply a temperature decrease. The scanning electron microscopy analysis of the drills demonstrated that little drill wear occurred up to 35 utilization times.

摘要

引言

在种植体植入部位制备过程中控制温度产生对于预防种植体早期失败很重要。

目的

本体外研究旨在使用旋转式和压电式手术器械测量初次截骨过程中产生的温度变化。

方法

根据钻头和器械类型、冷却量(毫升/分钟)和冷却温度定义了九组。在人工骨样本中总共进行了315次种植体植入部位制备,并使用红外热像仪测量温度。在基线以及使用10次和35次后,使用扫描电子显微镜评估钻头的磨损情况。

结果

压电式手术器械组导致的温度升高明显高于旋转式钻头组(<0.001)。在考虑旋转式钻头组时,从未记录到温度≥40°C的情况。

结论

较低的生理盐水温度意味着温度显著降低(<0.001),而冷却量的增加并不意味着温度降低。对钻头的扫描电子显微镜分析表明,在使用35次之前几乎没有钻头磨损。