Abstract

Managing complex benign airway disease is a major challenge in interventional pulmonology. With the introduction of additive manufacturing in the medical field, patient-specific (PS) implants are an innovate prospect for airway management. Historically, stents were oversized to resist migration. However, the optimal degree and impact of stent oversizing remains unclear. The ability to design stents based on computed tomography (CT) invites opportunity to understand sizing. Here, we report a novel three-dimensional (3D) image reconstruction tool to quantify fit repeatedly over time. Analysis of CT imaging before and after successive stent implants in a single patient with different areas of stenosis and malacia was done. Nine PS airway stents over 4 years (five left mainstem and four right mainstem) were studied. The distance between the airway model and stent was calculated. The CT images were correlated to stent designs in CloudCompare software (v2.10-alpha) for novel analysis. Heat map was exported depicting the distances between the airway and the stent to the clinician's prescribed stent model. Corresponding histograms containing distances, mean, and standard deviation were reported. It is possible to measure stent fit based on heat map quantification on patient imaging. Observation of the airway over time and stent change suggests that the airway became more open over time requiring increased stent diameters. The ability to design and measure stent fit over time can help quantify the utility and impact of PS silicone airway stent. The airway appears to display plasticity such that there is notable change in stent prescription over time.

摘要

管理复杂的良性气道疾病是介入肺病学的一大挑战。随着增材制造在医学领域的引入,患者特异性(PS)植入物成为气道管理的创新前景。历史上,支架被过度设计以防止迁移。然而,支架过度设计的最佳程度和影响仍不清楚。基于计算机断层扫描(CT)设计支架的能力为理解尺寸提供了机会。在这里,我们报告了一种新颖的三维(3D)图像重建工具,可随时间重复定量拟合。对一名患有不同狭窄和软化区域的患者的连续支架植入前后的 CT 成像进行了分析。在 4 年的时间里研究了 9 个 PS 气道支架(5 个左主支气管和 4 个右主支气管)。计算了气道模型和支架之间的距离。将 CT 图像与 CloudCompare 软件(v2.10-alpha)中的支架设计相关联,以进行新的分析。导出了热图,描绘了气道和支架之间的距离到临床医生规定的支架模型。报告了包含距离、平均值和标准差的相应直方图。可以基于患者影像学上的热图定量来测量支架的贴合度。随着时间的推移观察气道和支架的变化表明,气道随着时间的推移变得更加开放,需要增加支架直径。随着时间的推移设计和测量支架贴合度的能力可以帮助量化 PS 硅酮气道支架的效用和影响。气道似乎表现出可塑性,支架处方随时间有明显变化。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8429/10185860/92687c58e634/10.1177_17534666221137999-fig1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验