Suppr超能文献

妇科癌症中的 Tru-Cut 活检:充分性、准确性、安全性及临床适用性

Tru-Cut Biopsy in Gynecological Cancer: Adequacy, Accuracy, Safety and Clinical Applicability.

作者信息

Asp Mihaela, Mockute Ingrida, Måsbäck Anna, Liuba Karina, Kannisto Päivi, Malander Susanne

机构信息

Department of Obstetrics and Gynecology, Department of Clinical Science, Skåne University Hospital, Lund University, Lund, Sweden.

Department of Clinical Genetics and Pathology, Department of Clinical Science, Skåne University Hospital, Lund University, Lund, Sweden.

出版信息

J Multidiscip Healthc. 2023 May 15;16:1367-1377. doi: 10.2147/JMDH.S396788. eCollection 2023.

Abstract

PURPOSE

Tru-cut biopsy is a minimally invasive technique used to obtain tissue samples for the diagnosis of tumors, especially in patients where primary surgery is not indicated. The aim of this study was to assess the adequacy, accuracy and safety of the tru-cut biopsy for diagnosis in gynecological cancer.

METHODS

A retrospective population-based review of 328 biopsies was conducted. The indications for tru-cut biopsies were diagnosis of primary tumors, metastases of gynecological and non-gynecological tumors, and suspected recurrences. A tissue sample was considered adequate when the quality/quality was sufficient to identify the subtype/origin of the tumor. Potential factors affecting adequacy were analyzed using logistic regressions analyses. Accuracy was defined as agreement between the diagnosis of the tru-cut biopsy and the postoperative histology. The therapy plan was registered, and the clinical applicability of the tru-cut biopsy was investigated. Complications within 30 days after the biopsy procedure were registered.

RESULTS

In total, 300 biopsies were identified as tru-cut biopsies. The overall adequacy was 86.3%, varying between 80.8% and 93.5%, respectively, when performed by a gynecological oncologist or a gynecologist with a subspecialty in ultrasound diagnosis. Sampling of a pelvic mass had a lower adequacy (81.6%) compared with sampling of the omentum (93.9%) or carcinomatosis (91.5%). The accuracy was 97.5%, and the complication rate was 1.3%.

CONCLUSION

The tru-cut biopsy is a safe and reliable diagnostic method with a high accuracy and a good adequacy, depending on the site of the tissue sample, indications for the biopsy and the experience of the operator.

摘要

目的

切割活检是一种微创技术,用于获取组织样本以诊断肿瘤,特别是对于不适合进行初次手术的患者。本研究的目的是评估切割活检在妇科癌症诊断中的充分性、准确性和安全性。

方法

对328例活检进行基于人群的回顾性研究。切割活检的适应证包括原发性肿瘤的诊断、妇科和非妇科肿瘤的转移以及疑似复发。当组织样本的质量足以确定肿瘤的亚型/起源时,认为样本是充分的。使用逻辑回归分析潜在影响充分性的因素。准确性定义为切割活检诊断与术后组织学诊断的一致性。记录治疗方案,并研究切割活检的临床适用性。记录活检术后30天内的并发症。

结果

总共300例活检被确定为切割活检。总体充分性为86.3%,由妇科肿瘤学家或具有超声诊断亚专业的妇科医生进行时,分别在80.8%和93.5%之间变化。盆腔肿块的采样充分性(81.6%)低于大网膜采样(93.9%)或癌性腹膜炎采样(91.5%)。准确性为97.5%,并发症发生率为1.3%。

结论

切割活检是一种安全可靠的诊断方法,具有较高的准确性和良好的充分性,这取决于组织样本的部位、活检适应证和操作者的经验。