Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman, Kerman 76175-133, Iran.
Biosensors (Basel). 2023 May 7;13(5):524. doi: 10.3390/bios13050524.
The toxicity of commonly used drugs, such as acetaminophen (ACAP) and its degradation-derived metabolite of 4-aminophenol (4-AP), underscores the need to achieve an effective approach in their simultaneous electrochemical determination. Hence, the present study attempts to introduce an ultra-sensitive disposable electrochemical 4-AP and ACAP sensor based on surface modification of a screen-printed graphite electrode (SPGE) with a combination of MoS nanosheets and a nickel-based metal organic framework (MoS/Ni-MOF/SPGE sensor). A simple hydrothermal protocol was implemented to fabricate MoS/Ni-MOF hybrid nanosheets, which was subsequently tested for properties using valid techniques including X-ray diffraction (XRD), field emission-scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDX), Fourier transformed infrared spectroscopy (FTIR), and N adsorption-desorption isotherm. The 4-AP detection behavior on MoS/Ni-MOF/SPGE sensor was followed by cyclic voltammetry (CV), chronoamperometry and differential pulse voltammetry (DPV). Our experimental findings on the generated sensor confirmed a broad linear dynamic range (LDR) for 4-AP from 0.1 to 600 μM with a high sensitivity of 0.0666 μA/μM and a low limit of detection (LOD) of 0.04 μM. In addition, an analysis of real specimens such as tap water sample as well as a commercial sample (acetaminophen tablets) illuminated the successful applicability of as-developed sensor in determining ACAP and 4-AP, with an impressive recovery rate.
常用药物(如对乙酰氨基酚(ACAP)及其降解衍生的代谢物 4-氨基酚(4-AP))的毒性突出表明需要找到一种有效的方法来同时对其进行电化学测定。因此,本研究试图在基于丝网印刷石墨电极(SPGE)的表面修饰中引入一种超灵敏的一次性电化学 4-AP 和 ACAP 传感器,该修饰物结合了 MoS 纳米片和基于镍的金属有机骨架(MoS/Ni-MOF/SPGE 传感器)。采用简单的水热法制备了 MoS/Ni-MOF 杂化纳米片,并通过 X 射线衍射(XRD)、场发射扫描电子显微镜(FE-SEM)、能谱(EDX)、傅里叶变换红外光谱(FTIR)和氮气吸附-脱附等温线等有效技术对其性能进行了测试。在 MoS/Ni-MOF/SPGE 传感器上通过循环伏安法(CV)、计时安培法和差分脉冲伏安法(DPV)来研究 4-AP 的检测行为。在生成的传感器上进行的实验结果证实,4-AP 的宽线性动态范围(LDR)从 0.1 到 600 μM,灵敏度为 0.0666 μA/μM,检测限(LOD)低至 0.04 μM。此外,对实际样品(自来水样本和商业样本(对乙酰氨基酚片))的分析表明,所开发的传感器在确定 ACAP 和 4-AP 方面具有成功的适用性,且回收率令人印象深刻。