Suppr超能文献

重新思考失真产物耳声发射(DPOAE)信噪比的临床实用性。

Rethinking the clinical utility of distortion-product otoacoustic emission (DPOAE) signal-to-noise ratio.

机构信息

School of Speech, Language and Hearing Sciences, San Diego State University, San Diego, CA, USA.

Department of Otolaryngology-Head and Neck Surgery, Division of Audiology, Mayo Clinic, Rochester, MN, USA.

出版信息

Int J Audiol. 2024 Jul;63(7):491-499. doi: 10.1080/14992027.2023.2215943. Epub 2023 Jun 2.

Abstract

OBJECTIVE

Distortion-product otoacoustic emission (DPOAE) levels are repeatable over time in normal-hearing individuals making DPOAE levels an ideal measurement for monitoring cochlear status in clinic and research applications. However, if DPOAE signal-to-noise ratio (SNR) values instead of levels are used for monitoring, the repeatability of this value needs to be established. This retrospective, cross-sectional study sought to determine DPOAE SNR repeatability in younger children, older children, young adults and a patient population with normal hearing.

DESIGN

Each participant attended four sessions where DPOAE discrete frequency sweeps were collected at conventional (≤ 8 kHz) and/or extended-high frequencies (> 8 kHz). To examine the extent of variability to be expected for DPOAE SNR, average absolute SNR differences-between-trials were determined and compared to average absolute DPOAE level differences-between-trials.

STUDY SAMPLES

One hundred forty-five participants, incorporating four different groups from three different studies. Ages ranged from 3 to 55 years.

RESULTS

Average SNR differences-between-trials across all frequencies are greater than differences for average DPOAE levels. Improved calibration methods result in SNR differences-between-trials that are similar across all frequencies.

CONCLUSIONS

When monitoring cochlear health over an extended bandwidth, DPOAE levels are less variable across trials than SNR values, thus allowing earlier indicators of cochlear damage.

摘要

目的

在听力正常的个体中,畸变产物耳声发射(DPOAE)水平随时间具有可重复性,这使得 DPOAE 水平成为临床和研究应用中监测耳蜗状态的理想测量指标。然而,如果使用 DPOAE 信号噪声比(SNR)值而不是水平值来进行监测,则需要确定该值的可重复性。本回顾性、横断面研究旨在确定具有正常听力的年轻儿童、大龄儿童、年轻成年人和患者群体中 DPOAE SNR 的可重复性。

设计

每位参与者参加了四个阶段,在常规(≤8 kHz)和/或扩展高频(>8 kHz)下采集 DPOAE 离散频率扫描。为了研究 DPOAE SNR 的可变性程度,确定了平均绝对 SNR 试验间差异,并与平均绝对 DPOAE 水平试验间差异进行了比较。

研究样本

来自三个不同研究的四个不同组的 145 名参与者。年龄从 3 岁到 55 岁不等。

结果

所有频率的平均 SNR 试验间差异大于平均 DPOAE 水平的差异。改进的校准方法可使所有频率的 SNR 试验间差异相似。

结论

在扩展带宽监测耳蜗健康时,与 SNR 值相比,DPOAE 水平在试验间的变异性更小,因此可以更早地发现耳蜗损伤的迹象。

相似文献

1
Rethinking the clinical utility of distortion-product otoacoustic emission (DPOAE) signal-to-noise ratio.
Int J Audiol. 2024 Jul;63(7):491-499. doi: 10.1080/14992027.2023.2215943. Epub 2023 Jun 2.
2
A systematic review of stimulus parameters for eliciting distortion product otoacoustic emissions from adult humans.
Int J Audiol. 2017 Jun;56(6):382-391. doi: 10.1080/14992027.2017.1290282. Epub 2017 Feb 20.
4
Repeatability of high-frequency distortion-product otoacoustic emissions in normal-hearing adults.
Ear Hear. 2006 Oct;27(5):466-79. doi: 10.1097/01.aud.0000233892.37803.1a.
5
Dietary interventions for recurrent abdominal pain in childhood.
Cochrane Database Syst Rev. 2017 Mar 23;3(3):CD010972. doi: 10.1002/14651858.CD010972.pub2.
6
Sertindole for schizophrenia.
Cochrane Database Syst Rev. 2005 Jul 20;2005(3):CD001715. doi: 10.1002/14651858.CD001715.pub2.
7
Test-retest repeatability of distortion product otoacoustic emissions.
Ear Hear. 2008 Jun;29(3):378-91. doi: 10.1097/AUD.0b013e31816906e7.
8
Nebulised hypertonic saline for cystic fibrosis.
Cochrane Database Syst Rev. 2023 Jun 14;6(6):CD001506. doi: 10.1002/14651858.CD001506.pub5.
9
Washout policies in long-term indwelling urinary catheterisation in adults.
Cochrane Database Syst Rev. 2017 Mar 6;3(3):CD004012. doi: 10.1002/14651858.CD004012.pub5.
10
Positioning for acute respiratory distress in hospitalised infants and children.
Cochrane Database Syst Rev. 2022 Jun 6;6(6):CD003645. doi: 10.1002/14651858.CD003645.pub4.

本文引用的文献

2
High-Frequency Distortion-Product Otoacoustic Emission Repeatability in a Patient Population.
Ear Hear. 2018 Jan/Feb;39(1):85-100. doi: 10.1097/AUD.0000000000000465.
3
Compensating for ear-canal acoustics when measuring otoacoustic emissions.
J Acoust Soc Am. 2017 Jan;141(1):515. doi: 10.1121/1.4973618.
4
Serial Monitoring of Otoacoustic Emissions in Clinical Trials.
Otol Neurotol. 2016 Sep;37(8):e286-94. doi: 10.1097/MAO.0000000000001134.
6
Comparison of nine methods to estimate ear-canal stimulus levels.
J Acoust Soc Am. 2014 Oct;136(4):1768-87. doi: 10.1121/1.4894787.
8
Further assessment of forward pressure level for in situ calibration.
J Acoust Soc Am. 2011 Dec;130(6):3882-92. doi: 10.1121/1.3655878.
9
Distribution of standing-wave errors in real-ear sound-level measurements.
J Acoust Soc Am. 2011 May;129(5):3134-40. doi: 10.1121/1.3569726.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验