储存过程中分离的有丝分裂器的稳定性

STABILITY OF ISOLATED MITOTIC APPARATUS DURING STORAGE.

作者信息

Forer Arthur, Zimmerman A M

机构信息

Biology Department, York University, Downsview, Ontario M3J 1P3, Canada.

Zoology Department, University of Toronto, Ontario, Canada.

出版信息

Dev Growth Differ. 1978;20(2):93-105. doi: 10.1111/j.1440-169X.1978.00093.x.

Abstract

Mitotic apparatus (MA) were isolated from sea urchin zygotes using various isolation procedures, and various properties of the isolated MA were studied and compared. MA isolated using hexylene glycol had birefringences which depended on the pH of the isolation medium, the lower the pH the higher the MA birefringence. The stability of the MA Birefringence also depended on the pH of the hexylene glycol isolation medium (the lower the pH the slower the rate of decay of birefringence), as did the final birefringence reached after prolonged storage. MA isolated using glycerol-dimethylsulphoxide (MTME) had much more stable birefringence than MA isolated using hexylene glycol; their birefringence decay rates were about 1000 times slower than those of MA isolated using hexylene glycol. Birefringence which remained after extraction of MA with H O, or 0.5 M KC1 was also studied; the results depended on the MA isolation medium, on the medium the MA were stored in, and on the amount of time the MA were stored after isolation, as described in detail in the text. These results are discussed, and it is suggested that several components (including, perhaps, oriented ribosomes) contribute to birefringence of isolated MA.

摘要

使用各种分离程序从海胆受精卵中分离出有丝分裂器(MA),并对分离出的MA的各种特性进行了研究和比较。用己二醇分离出的MA具有双折射,其取决于分离介质的pH值,pH值越低,MA双折射越高。MA双折射的稳定性也取决于己二醇分离介质的pH值(pH值越低,双折射衰减速率越慢),长时间储存后达到的最终双折射也是如此。用甘油 - 二甲基亚砜(MTME)分离出的MA比用己二醇分离出的MA具有更稳定的双折射;它们双折射的衰减速率比用己二醇分离出的MA慢约1000倍。还研究了用H₂O或0.5 M KCl提取MA后剩余的双折射;结果取决于MA分离介质、MA储存的介质以及MA分离后储存的时间,文中对此有详细描述。对这些结果进行了讨论,并提出几种成分(可能包括定向核糖体)对分离出的MA的双折射有贡献。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验