Stem alignment with short tapered-wedge cementless stems affects bone mineral density continuously for at least 5 years after primary total hip arthroplasty.

机构信息

Department of Orthopaedic Surgery, Shiraniwa Hospital Joint Arthroplasty Centre, Nara, Japan.

Department of Orthopaedic Surgery, Osaka Saiseikai Nakatsu Hospital, Osaka, Japan.

出版信息

Hip Int. 2024 Jan;34(1):57-65. doi: 10.1177/11207000231178984. Epub 2023 Jun 9.

Abstract

AIM

This study aimed to assess the relationship between the three-dimensional (3D) alignment of short tapered-wedge cementless stems and bone mineral density (BMD) changes in patients followed up for 5 years after total hip arthroplasty (THA).

METHODS

We retrospectively analysed the hips of 52 patients who underwent THA using short tapered-wedge cementless stems at our institution from 2013 to 2016 with complete 5-year follow-up data. We evaluated the relationship between stem alignment, measured using a 3D-templating software, and BMD changes in the 7 Gruen zones.

RESULTS

After 1 year, significant negative correlations between varus insertion and a decrease in BMD in zone 7 and between flexed insertion and decreases in BMD in zones 3 and 4 were noted. After 5 years, significant negative correlations between varus insertion and a decrease in BMD in zone 7 and between flexed insertion and decreases in BMD zones 2, 3, and 4 were observed. With increased amounts of varus/flexion stem alignment, the amount of BMD loss decreased. There was no correlation between anteverted stem insertion and changes in BMD levels.

CONCLUSIONS

Our data showed that stem alignment affects BMD based on 5-year follow-up data after surgery. Careful observation is necessary, especially when using short tapered-wedge cementless stems, as stem alignment may affect changes in BMD levels more than 5 years after surgery.

摘要

目的

本研究旨在评估全髋关节置换术后 5 年随访中,短锥形骨水泥型非骨水泥股骨柄三维(3D)对线与骨密度(BMD)变化之间的关系。

方法

我们回顾性分析了 2013 年至 2016 年在我院接受短锥形骨水泥型非骨水泥股骨柄全髋关节置换术的 52 例患者的髋关节,所有患者均获得了完整的 5 年随访资料。我们评估了使用 3D 模板软件测量的柄对线与 7 个Gruen 区 BMD 变化之间的关系。

结果

术后 1 年,发现内翻插入与 7 区 BMD 下降之间,以及前屈插入与 3 区和 4 区 BMD 下降之间存在显著负相关。术后 5 年,发现内翻插入与 7 区 BMD 下降之间,以及前屈插入与 2 区、3 区和 4 区 BMD 下降之间存在显著负相关。随着内翻/前屈角度的增加,BMD 丢失量减少。前倾柄插入与 BMD 水平变化之间无相关性。

结论

我们的数据表明,术后 5 年随访时,柄对线会影响 BMD。尤其是使用短锥形骨水泥型非骨水泥股骨柄时,需要密切观察,因为柄对线可能会影响术后 5 年以上的 BMD 水平变化。