Suppr超能文献

成人三轴腕部和腰部加速度计测量运动行为的绝对强度阈值。

Absolute intensity thresholds for tri-axial wrist and waist accelerometer-measured movement behaviors in adults.

机构信息

School of Public Health, The University of Queensland, Queensland, Brisbane, Australia.

Post-graduate Program in Epidemiology, Federal University of Pelotas, Pelotas, Brazil.

出版信息

Scand J Med Sci Sports. 2023 Sep;33(9):1752-1764. doi: 10.1111/sms.14416. Epub 2023 Jun 12.

Abstract

AIM

This study was aimed to: (1) compare raw triaxial acceleration data from GENEActiv (GA) and ActiGraph GT3X+ (AG) placed on the non-dominant wrist; (2) compare AG placed on the non-dominant and dominant wrist, and waist; (3) derive brand- and placement-specific absolute intensity thresholds for inactive and sedentary time, and physical activity intensity in adults.

METHODS

Eighty-six adults (44 men; 34.6 ± 10.8 years) performed nine activities while simultaneously wearing GA and AG on wrist and waist. Acceleration (in gravitational equivalent units; mg) was compared with oxygen uptake (measured with indirect calorimetry).

RESULTS

Increases in acceleration mirrored increases in intensity of activities, regardless of device brand and placement. Differences in acceleration between GA and AG worn at the non-dominant wrist were small but tended to be high at lower intensity activities. Thresholds for differentiating inactivity (<1.5 MET) from activity (≥1.5 MET) ranged from 25 mg (AG non-dominant wrist; sensitivity 93%, specificity 95%) to 40 mg (AG waist; sensitivity 78%, specificity 100%). For moderate intensity (≥3 METs), thresholds ranged from 65 mg (AG waist; sensitivity 96%, specificity 94%) to 92 mg (GA non-dominant; sensitivity 93%, specificity 98%); vigorous intensity (≥6 METs) thresholds ranged from 190 mg (AG waist; sensitivity 82%, specificity 92%) to 283 mg (GA non-dominant; sensitivity 93%, specificity 98%).

CONCLUSION

Raw triaxial acceleration outputs from two widely used accelerometer brands may have limited comparability in low intensity activities. Thresholds derived in this study can be utilized in adults to reasonably classify movement behaviors into categories of intensity.

摘要

目的

本研究旨在:(1)比较放置在非优势手腕上的 GENEActiv(GA)和 ActiGraph GT3X+(AG)的原始三轴加速度数据;(2)比较放置在非优势手腕和优势手腕以及腰部的 AG;(3)为成年人的非活动和久坐时间以及身体活动强度推导品牌和放置特定的绝对强度阈值。

方法

86 名成年人(44 名男性;34.6±10.8 岁)同时在手腕和腰部佩戴 GA 和 AG 进行了九项活动。加速度(以重力等效单位表示;mg)与耗氧量(通过间接量热法测量)进行了比较。

结果

无论设备品牌和放置位置如何,加速度的增加都反映了活动强度的增加。GA 和 AG 佩戴在非优势手腕时的加速度差异较小,但在低强度活动时往往较高。区分非活动(<1.5 MET)和活动(≥1.5 MET)的阈值范围为 25mg(AG 非优势手腕;敏感性 93%,特异性 95%)至 40mg(AG 腰部;敏感性 78%,特异性 100%)。对于中等强度(≥3 METs),阈值范围为 65mg(AG 腰部;敏感性 96%,特异性 94%)至 92mg(GA 非优势手腕;敏感性 93%,特异性 98%);剧烈强度(≥6 METs)的阈值范围为 190mg(AG 腰部;敏感性 82%,特异性 92%)至 283mg(GA 非优势手腕;敏感性 93%,特异性 98%)。

结论

两种广泛使用的加速度计品牌的原始三轴加速度输出在低强度活动中可能具有有限的可比性。本研究中得出的阈值可用于成年人将运动行为合理地分类为强度类别。