Department of Electrical Engineering, Feng Chia University, Taichung, 40724, Taiwan.
Ph.D. Program in Electrical and Communications Engineering, Feng Chia University, Taichung, 40724, Taiwan.
Int Ophthalmol. 2023 Sep;43(9):3309-3319. doi: 10.1007/s10792-023-02735-w. Epub 2023 Jun 17.
Glare visual acuity and contrast sensitivity are important indicators of visual quality. Studies have shown that the glare visual acuity and contrast sensitivity in dry eye patients tend to degenerate, further affecting their quality of life. The objective of this study was to investigate the effect of notch filters on glare VA and contrast sensitivity in patients with dry eye or with dry eye syndrome.
36 subjects in the 20‒65 age group were diagnosed as having dry eye disease or perceived dry eye syndromes themselves who were included after the initial screening with the OSDI questionnaire, and one was subsequently excluded as they had undergone retinal detachment surgery. Finally, 35 subjects (14 male and 21 female) with a mean age of 40.66 ± 15.62 years participated in this study. All subjects wore their habitual prescriptions and four different filter lenses (namely 480, 620, dual 480 & 620 notch filter, and FL-41 tinted lens), and measured the parameters of glare visual acuity and contrast sensitivity using CSV-1000 and sine wave contrast test (SWCT), respectively. Student t-test and Repeated measurement analysis (R-ANOVA) were utilized by using SPSS 26.0 software.
A dual-wavelength 480 & 620 nm optical notch filter had a significant anti-glare effect decreasing glare disabilities or discomfort, and leading to better visual quality, the same effect was also shown on a 480 nm notch filter lens. All participants showed a significant difference among the baseline, three notch filters (480 nm, 620 nm, dual-wavelength 480 & 620 nm), and FL-41 tinted lens were used on SWCT_A (1.5 cpd, F = 3.054, p = 0.019) and SWCT_E (18 cpd, F = 2.840, p = 0.049); but did not show statistical different on SWCT_B (3 cpd, F = 0.333, p = 0.771), SWCT_C (6 cpd, F = 1.779, p = 0.159), and SWCT_D (12 cpd, F = 1.447, p = 0.228). The baseline showed the best visual performance on CS at a low spatial frequency (SWCT_A, 1.5 cpd), any filter might reduce the contrast sensitivity at low spatial frequencies in the clinical trial, whereas 480 nm notch filter showed the best effectiveness on CS at a high spatial frequency (SWCT_E, 18 cpd), the FL-41 lens that also filters out the 480 nm band does not achieve the same effect. Moreover, patients with dry eye or those older than 40 years old preferred optical multilayer notch filters to FL-41 tinted lenses.
The 480- & 620-nm dual-wavelength and 480-nm single-wavelength notch filters have the best effect on the glare visual acuity and contrast sensitivity (CS) at high spatial frequencies in dry eye patients. The 620-nm notch filter performs better in CS at low and mid-low spatial frequencies; the FL-41 tinted lens performs poorly for glare VA and CS spatial frequencies examination. Patients with glare disabilities or CS disturbance at high spatial frequencies may choose a 480-nm notch filter lens, and patients who have CS disturbance at low spatial frequencies may consider a 620-nm notch filter for the prescription.
眩光视力和对比敏感度是视觉质量的重要指标。研究表明,干眼症患者的眩光视力和对比敏感度往往会下降,进一步影响他们的生活质量。本研究的目的是探讨缺口滤光片对干眼症或干眼症综合征患者的眩光视力和对比敏感度的影响。
通过初始 OSDI 问卷筛查,纳入 36 名年龄在 20-65 岁的干眼症患者或自我诊断为干眼症的患者,排除 1 名因视网膜脱离手术而被排除的患者,最终有 35 名受试者(14 名男性和 21 名女性)参与了本研究,平均年龄为 40.66±15.62 岁。所有受试者均佩戴其惯用处方,并分别佩戴四种不同的滤光镜(即 480、620、双波长 480 & 620 缺口滤光镜和 FL-41 有色镜片),并使用 CSV-1000 和正弦波对比测试(SWCT)分别测量眩光视力和对比敏感度参数。使用 SPSS 26.0 软件进行学生 t 检验和重复测量分析(R-ANOVA)。
双波长 480 & 620nm 光学缺口滤光片对眩光有明显的抗眩光效果,降低了眩光障碍或不适,提高了视觉质量,480nm 缺口滤光镜也有同样的效果。所有参与者在基线、三种滤光镜(480nm、620nm、双波长 480 & 620nm)和 FL-41 有色镜片在 SWCT_A(1.5cpd,F=3.054,p=0.019)和 SWCT_E(18cpd,F=2.840,p=0.049)之间的 SWCT_A 和 SWCT_E 之间存在显著差异;但在 SWCT_B(3cpd,F=0.333,p=0.771)、SWCT_C(6cpd,F=1.779,p=0.159)和 SWCT_D(12cpd,F=1.447,p=0.228)之间没有统计学差异。在低空间频率(SWCT_A,1.5cpd)下,基线的视觉表现最佳,任何滤光片都可能降低临床研究中低空间频率下的对比敏感度,而 480nm 缺口滤光片在高空间频率(SWCT_E,18cpd)下的对比敏感度效果最佳,同样过滤出 480nm 波段的 FL-41 镜片却无法达到相同的效果。此外,干眼症患者或 40 岁以上的患者更喜欢使用光学多层缺口滤光片而不是 FL-41 有色镜片。
480-和 620nm 双波长和 480nm 单波长缺口滤光片对干眼症患者的高空间频率眩光视力和对比敏感度(CS)有最佳效果。620nm 缺口滤光片在低和中低空间频率的 CS 中表现更好;FL-41 有色镜片在眩光 VA 和 CS 空间频率检查中的效果较差。高空间频率眩光障碍或 CS 障碍的患者可能会选择 480nm 缺口滤光镜,而低空间频率 CS 障碍的患者可能会考虑使用 620nm 缺口滤光镜进行处方配镜。