Suppr超能文献

种植体周围黏膜厚度的无创评估:一项横断面研究。

Non-invasive assessment of peri-implant mucosal thickness: A cross-sectional study.

机构信息

Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland.

Division of Fixed Prosthodontics and Occlusion, School of Dental Medicine, University of Geneva, Geneva, Switzerland.

出版信息

J Periodontol. 2023 Nov;94(11):1315-1323. doi: 10.1002/JPER.23-0102. Epub 2023 Jun 18.

Abstract

BACKGROUND

This study aimed to evaluate the reliability and reproducibility of different non-invasive methods for the assessment of peri-implant mucosal thickness.

METHODS

Subjects with two adjacent dental implants in the central maxillary region were included in this study. Three different methods to assess facial mucosal thickness (FMT) were compared: digital file superimposition using Digital Imaging and Communication in Medicine (DICOM) and stereolithography (STL) files of the arch of interest (DICOM-STL), DICOM files alone, and non-ionizing ultrasound (US). Inter-rater reliability agreements between different assessment methods were analyzed using inter-class correlation coefficients (ICCs).

RESULTS

A total of 50 subjects with 100 bone-level implants constituted the study population. Assessment of FMT using STL and DICOM files demonstrated excellent inter-rater reliability agreement. Mean ICC values of 0.97 and 0.95 were observed in the DICOM-STL and DICOM groups, respectively. Comparison between the DICOM-STL and US revealed good agreement, with an ICC of 0.82 (95% CI: 0.74 to 0.88) and a mean difference of -0.13 ± 0.50 mm (-1.13 to 0.86). Comparison between DICOM files alone versus US showed good agreement, with an ICC of 0.81 (95% CI: 0.73 to 0.89) and a mean difference of -0.23 ± 0.46 mm (-1.12 to 0.67). Comparison between DICOM-STL and DICOM files revealed excellent agreement, with an ICC of 0.94 (95% CI: 0.91 to 0.96) and a mean difference of 0.1 ± 0.29 mm (LOA -0.47 to 0.46).

CONCLUSIONS

Quantification of peri-implant mucosal thickness via analysis of DICOM-STL files, DICOM files, or US assessment are comparably reliable and reproducible methods.

摘要

背景

本研究旨在评估不同非侵入性方法评估种植体周围黏膜厚度的可靠性和可重复性。

方法

本研究纳入了上颌中央区有两个相邻牙种植体的受试者。比较了三种不同的评估颊侧黏膜厚度(FMT)的方法:感兴趣的牙弓的数字成像和通信(DICOM)和立体光刻(STL)文件的数字文件叠加(DICOM-STL)、单独的 DICOM 文件和非电离超声(US)。使用组内相关系数(ICC)分析不同评估方法之间的观察者间可靠性协议。

结果

共有 50 名受试者(100 个骨水平种植体)构成了研究人群。使用 STL 和 DICOM 文件评估 FMT 显示出极好的观察者间可靠性一致性。DICOM-STL 组和 DICOM 组的平均 ICC 值分别为 0.97 和 0.95。DICOM-STL 与 US 之间的比较显示出良好的一致性,ICC 为 0.82(95%CI:0.74 至 0.88),平均差异为-0.13±0.50mm(-1.13 至 0.86)。单独的 DICOM 文件与 US 之间的比较显示出良好的一致性,ICC 为 0.81(95%CI:0.73 至 0.89),平均差异为-0.23±0.46mm(-1.12 至 0.67)。DICOM-STL 与 DICOM 文件之间的比较显示出极好的一致性,ICC 为 0.94(95%CI:0.91 至 0.96),平均差异为 0.1±0.29mm(LOA -0.47 至 0.46)。

结论

通过分析 DICOM-STL 文件、DICOM 文件或 US 评估来量化种植体周围黏膜厚度是可靠且可重复的方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验