通过摆动磁力测定法研究人体稳定性。

Stability of the human body investigated by sway magnetometry.

作者信息

Dean E M, Griffiths C J, Murray A

出版信息

J Med Eng Technol. 1986 May-Jun;10(3):126-30. doi: 10.3109/03091908609022899.

DOI:10.3109/03091908609022899
PMID:3735381
Abstract

A new technique using a pre-calibrated magnetometer has been used to investigate the stability of the human body. Transducer coils were attached to a belt which was worn by the subject. Sway was measured over 30 s periods with eyes open and eyes closed. For 10 normal subjects, the mean sway speed was 3.6 +/- 0.9 mm/s with eyes open, and 5.3 +/- 1.5 mm/s with eyes closed. The mean ratio for eyes open to eyes closed was 0.68 +/- 0.10. The test was simple to perform and gave reproducible results.

摘要

一种使用预校准磁力计的新技术已被用于研究人体的稳定性。换能器线圈附着在受试者佩戴的腰带上。在受试者睁眼和闭眼的情况下,测量其30秒内的摇摆情况。对于10名正常受试者,睁眼时的平均摇摆速度为3.6±0.9毫米/秒,闭眼时为5.3±1.5毫米/秒。睁眼与闭眼的平均比值为0.68±0.10。该测试操作简单,结果具有可重复性。

相似文献

1
Stability of the human body investigated by sway magnetometry.通过摆动磁力测定法研究人体稳定性。
J Med Eng Technol. 1986 May-Jun;10(3):126-30. doi: 10.3109/03091908609022899.
2
Comparison of body sway analysis techniques. Assessment with subjects standing on a stable surface.身体摇摆分析技术的比较。对站在稳定表面上的受试者进行评估。
Acta Otolaryngol. 1994 Mar;114(2):115-9. doi: 10.3109/00016489409126028.
3
Comparison of balance assessment by sway magnetometry and force platforms.摇摆磁力测定法与测力平台平衡评估的比较
Arch Otolaryngol Head Neck Surg. 1993 Jan;119(1):41-6. doi: 10.1001/archotol.1993.01880130043005.
4
Repeatability of body sway measurements; day-to-day variation measured by sway magnetometry.身体摇摆测量的可重复性;通过摇摆磁力测定法测量的每日变化。
Physiol Meas. 1998 May;19(2):159-64. doi: 10.1088/0967-3334/19/2/003.
5
Postural stability of normal subjects measured by sway magnetometry: pathlength and area for the age range 15 to 64 years.
Physiol Meas. 1998 Feb;19(1):103-9. doi: 10.1088/0967-3334/19/1/009.
6
Postural stability of preoperative acoustic neuroma patients assessed by sway magnetometry: are they unsteady?通过摆动磁强计评估术前听神经瘤患者的姿势稳定性:他们是否不稳定?
Laryngoscope. 2003 Apr;113(4):640-2. doi: 10.1097/00005537-200304000-00010.
7
Influence of the visual environment on the postural stability in healthy older women.视觉环境对健康老年女性姿势稳定性的影响。
Gerontology. 2002 Sep-Oct;48(5):293-7. doi: 10.1159/000065252.
8
Balance in a rotating artificial gravity environment.旋转人工重力环境中的平衡。
Exp Brain Res. 2003 Jan;148(2):266-71. doi: 10.1007/s00221-002-1300-9. Epub 2002 Nov 22.
9
Postural sway in amputees and normal subjects.
J Bone Joint Surg Am. 1978 Oct;60(7):895-8.
10
Do patients with ankylosing spondylitis have poorer balance than normal subjects?强直性脊柱炎患者的平衡能力是否比正常人差?
Rheumatology (Oxford). 2000 May;39(5):497-500. doi: 10.1093/rheumatology/39.5.497.

引用本文的文献

1
Balance measured by head (and trunk) tracking and a force platform in chemically (PCB and TCE) exposed and referent subjects.通过头部(和躯干)追踪以及测力平台对化学物质(多氯联苯和三氯乙烯)暴露组和对照组受试者进行平衡测量。
Occup Environ Med. 1994 Jun;51(6):381-5. doi: 10.1136/oem.51.6.381.
2
Problem with the use of total distance travelled and average speed as measures of postural sway.将行走的总距离和平均速度用作姿势摆动测量指标的问题。
Med Biol Eng Comput. 1990 Nov;28(6):601-2. doi: 10.1007/BF02442615.