Suppr超能文献

通过超声剪切波弹性成像技术探讨影响睾丸弹性的解剖学因素:初步结果。

Exploring the anatomical factors influencing testes elasticity via ultrasound shear wave elastography: Preliminary results.

机构信息

Department of Ultrasound, The Second Affiliated Hospital of Guangzhou Medical University, Guangzhou 510260, China.

Department of Ultrasound, The Second Affiliated Hospital of Guangzhou Medical University, Guangzhou 510260, China.

出版信息

Rev Int Androl. 2023 Oct-Dec;21(4):100367. doi: 10.1016/j.androl.2023.100367. Epub 2023 Jul 7.

Abstract

PURPOSE

The aim of this study is to evaluate the anatomical factors influencing elasticity values of normal testicular parenchyma using shear wave elastography (SWE).

METHODS

This study examined 68 healthy male volunteers (117 testes in which standard transverse axis ultrasonography views could be obtained) via conventional scrotal ultrasonography and SWE. Both the mean (E) and standard deviation (E) elasticity values were acquired.

RESULTS

In the standard transverse axis view of the rete testis at the mid-lateral edge of the testes, the E values in 2mm the testicular parenchyma from the rete testis and the testicular capsule at the same level as the rete testis were all significantly larger than in the central zone (P<0.001, P<0.001, respectively). The E value in the testicular parenchyma 2mm from the testicular capsule on the line formed approximately 45° below the horizontal line of the rete testis was significantly larger than in the rete testis approximately 45° above the horizontal line (P<0.001). In two standard transverse axis views, the E values in other regions were significantly larger than those in the central zones (all P<0.001). Also, the E values in the transmediastinal arteries were larger than those of the surrounding normal testicular parenchyma (P<0.001).

CONCLUSION

Based on SWE, factors including the testicular capsule, the density of testicular fibrous septa, the depth of the Q-Box™, and the transmediastinal artery may influence the testes elasticity measurement.

摘要

目的

本研究旨在通过剪切波弹性成像(SWE)评估影响正常睾丸实质弹性值的解剖学因素。

方法

本研究通过常规阴囊超声和 SWE 检查了 68 名健康男性志愿者(117 个睾丸,可获得标准横切轴超声图像)。获得了平均(E)和标准偏差(E)弹性值。

结果

在睾丸网位于睾丸中侧边缘的标准横切轴视图中,睾丸实质从睾丸网到睾丸网和睾丸网同一水平的睾丸囊 2mm 处的 E 值均明显大于中央区(P<0.001,P<0.001)。在睾丸网下方约 45°的水平线形成的睾丸囊线上,睾丸实质 2mm 处的 E 值明显大于睾丸网上方约 45°的水平线(P<0.001)。在两个标准横切轴视图中,其他区域的 E 值明显大于中央区(均 P<0.001)。此外,纵隔内动脉的 E 值大于其周围正常睾丸实质的 E 值(P<0.001)。

结论

基于 SWE,睾丸囊、睾丸纤维隔密度、Q-Box™深度和纵隔内动脉等因素可能会影响睾丸弹性测量。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验