Abstract

INTRODUCTION

In this study, a new probe was designed to enable electrocardiography of a rotated heart during cardiac surgery when skin electrodes became non-functional. This probe adhered non-invasively to the epicardium and collected the ECG signal independently from the position of the heart. The study compared the accuracy of cardiac ischemia detection between classic skin and epicardial electrodes in an animal model.

METHODS

Using six pigs, an open chest model was devised with cardiac ischemia induction by coronary artery ligation in two non-physiologic heart positions. Both the accuracy and the time of detection of electrocardiographic symptoms of acute cardiac ischemia were compared between skin and epicardial methods of signal collection.

RESULTS

Heart rotation to expose either the anterior or the posterior wall resulted in a distortion or loss of the ECG signal collected by skin electrodes after coronary artery ligation, standard skin ECG monitoring did not reveal any ischemia symptoms. Attachment of an epicardial probe on the anterior and posterior walls helped in the recovery of the normal ECG wave. After ligation of the coronary artery, the epicardial probes recorded cardiac ischemia within 40 s.

DISCUSSION

This study highlighted the effectiveness of ECG monitoring with epicardial probes in a rotated heart. It can be concluded that epicardial probes can detect the presence of acute ischemia of a rotated heart when skin ECG monitoring becomes ineffective.

摘要

引言

在本研究中,设计了一种新型探头,以便在心脏手术期间皮肤电极失去功能时对旋转心脏进行心电图检查。该探头以非侵入方式附着于心外膜,并独立于心脏位置采集心电图信号。本研究在动物模型中比较了经典皮肤电极和心外膜电极检测心脏缺血的准确性。

方法

使用六头猪,设计了一种开胸模型,在两个非生理心脏位置通过冠状动脉结扎诱导心脏缺血。比较了皮肤和心外膜信号采集方法检测急性心脏缺血心电图症状的准确性和时间。

结果

心脏旋转以暴露前壁或后壁导致冠状动脉结扎后皮肤电极采集的心电图信号失真或丢失,标准皮肤心电图监测未显示任何缺血症状。在心外膜前壁和后壁附着探头有助于恢复正常心电图波形。冠状动脉结扎后,心外膜探头在40秒内记录到心脏缺血。

讨论

本研究强调了在心外膜探头进行心电图监测对旋转心脏的有效性。可以得出结论,当皮肤心电图监测无效时,心外膜探头可以检测旋转心脏急性缺血的存在。