Kızılkaya Ertan, Köse Nezire, Ünsal Delialioğlu Sibel, Karakaya Jale, Fil Balkan Ayla
Vocational School of Health Services, Yüksek İ̇htisas University, Ankara, Turkey.
Faculty of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Turkey.
Top Stroke Rehabil. 2024 Mar;31(2):145-156. doi: 10.1080/10749357.2023.2235800. Epub 2023 Jul 18.
Patients experience falls frequently after stroke. Preserved or acquired balance skills decrease fall risk and improve independence. Feasibility of Fullerton Advanced Balance Scale (FAB) has been shown in balance assessment in some neurological diseases except stroke.
The purpose of this study was to investigate the reliability and validity of Turkish version of FAB (FAB-T) in patients with stroke (PwS).
This cross-sectional study included 51 PwS (60.64 ± 7.66 years). Reliability analyses were conducted with Cronbach's alpha, intraclass correlation coefficient (ICC), and Spearman correlation analysis. Intra-rater and inter-rater reliability were assessed with three raters. FAB-T, Stroke Rehabilitation Assessment of Movement (STREAM), Brunnstrom Recovery Stages (BRS), Barthel Index (BI), and 36-Item Short Form Health Survey (SF-36) were used for convergent validity. Correlations of FAB-T with Berg Balance Scale (BBS) and Mini-Balance Evaluation Systems Test (Mini-BESTest) were measured for concurrent validity. Spearman correlation analysis was used for convergent and concurrent validity. For predictive validity patients' self-reports of falling were analyzed with ROC.
Intra-rater (ICC = 0.998) and inter-rater reliability (ICCs = 0.984; 0.984; 0.990), and internal consistency (Cronbach's alpha = 0.930) were excellent. FAB-T had good correlations with STREAM (ρ = 0.677) and BI (ρ = 0.628), moderate correlations with BRS (ρ = 0.504 and ρ = 0.579) and physical function of SF-36 (ρ = 0.436). FAB-T excellently correlated with Mini-BESTest and BBS (ρ = 0.928 and ρ = 0.942). The cutoff score of FAB-T was determined to be 21.5 points, with sensitivity of 84% and specificity of 61% (AUC = 0.749).
FAB-T is a reliable and valid balance assessment tool with an acceptable accuracy of fall prediction in PwS.
中风后患者经常跌倒。保留或获得的平衡技能可降低跌倒风险并提高独立性。除中风外,富勒顿高级平衡量表(FAB)在某些神经系统疾病的平衡评估中已显示出可行性。
本研究旨在调查土耳其语版FAB(FAB-T)在中风患者(PwS)中的可靠性和有效性。
这项横断面研究纳入了51例PwS(60.64±7.66岁)。采用克朗巴哈系数、组内相关系数(ICC)和斯皮尔曼相关分析进行可靠性分析。由三名评估者评估评估者内和评估者间的可靠性。使用FAB-T、运动中风康复评估(STREAM)、布伦斯特伦恢复阶段(BRS)、巴氏指数(BI)和36项简短健康调查(SF-36)进行收敛效度分析。测量FAB-T与伯格平衡量表(BBS)和迷你平衡评估系统测试(Mini-BESTest)的相关性以进行同时效度分析。斯皮尔曼相关分析用于收敛效度和同时效度分析。对于预测效度,使用ROC分析患者的跌倒自我报告。
评估者内(ICC = 0.998)和评估者间可靠性(ICC分别为0.984;0.984;0.990)以及内部一致性(克朗巴哈系数 = 0.930)都非常出色。FAB-T与STREAM(ρ = 0.677)和BI(ρ = 0.628)有良好的相关性,与BRS(ρ = 0.504和ρ = 0.579)以及SF-36的身体功能(ρ = 0.436)有中等相关性。FAB-T与Mini-BESTest和BBS有极好的相关性(ρ = 0.928和ρ = 0.942)。FAB-T的临界值确定为21.5分,敏感性为84%,特异性为61%(AUC = 0.749)。
FAB-T是一种可靠且有效的平衡评估工具,在PwS中对跌倒预测具有可接受的准确性。