This study aims to explore the measurement of the angle between the axis of the pedicle and the lateral margin of the isthmus on the lumbar spine, and investigate its clinical significance.
The angle was measured on 120 normal adults' X-ray and 25 dry anatomical specimens. 60 screws were placed by junior residents on 6 wet specimens through the freehand technique. 30 screws were placed on one side with their original experience. After learning the techniques mentioned in the study, 30 screws were placed on the other side. The specimens were examined by X-ray and CT, and the angles of the screw paths and the integrity of the pedicle were evaluated.
The angles of 120 subjects and 25 anatomical specimens show a gradually increasing trend. The differences among each segment were statistically significant (P < 0.05), but the difference in the same segment between the X-ray and the anatomical specimens was not statistically significant (P > 0.05). Furthermore, the differences in L1, L2, and L3 between the two genders were not statistically significant (P > 0.05). However, the angles were larger in female group than in male group in L4 and L5, and the differences were statistically significant (P < 0.05). The difference in the deviation rate of screw placement before and after the learning was statistically significant only in the L5 segment (P < 0.05). The difference in overall excellence rate was statistically significant (P < 0.05).
The measurement of the angle between the axis of the pedicle and the lateral margin of the isthmus on the lumbar can improve the accuracy of the lumbar sagittal screw angle.
本研究旨在探讨腰椎椎弓根轴与峡部外侧缘之间角度的测量方法,并探讨其临床意义。
在 120 例正常成年人 X 线片和 25 例干解剖标本上测量该角度。由初级住院医师通过徒手技术在 6 个湿标本上放置 60 个螺钉。其中 30 个螺钉按其原始经验放置在一侧。在学习了本研究中提到的技术后,在另一侧放置 30 个螺钉。通过 X 射线和 CT 检查标本,评估螺钉路径的角度和椎弓根的完整性。
120 名受试者和 25 个解剖标本的角度呈逐渐增加的趋势。各节段之间的差异具有统计学意义(P<0.05),但 X 射线和解剖标本同一节段之间的差异无统计学意义(P>0.05)。此外,L1、L2 和 L3 两个性别之间的角度差异无统计学意义(P>0.05)。然而,L4 和 L5 中女性组的角度大于男性组,差异具有统计学意义(P<0.05)。学习前后螺钉放置偏差率的差异仅在 L5 节段具有统计学意义(P<0.05)。整体优秀率的差异具有统计学意义(P<0.05)。
测量腰椎椎弓根轴与峡部外侧缘之间的角度可以提高腰椎矢状螺钉角度的准确性。