Leroux Charles, Ouadi Sarah, Leahy Conor, Marc Isabelle, Fontvieille Christophe, Bardin Fabrice
Laboratoire MIPA, Université de Nîmes, Sites des Carmes, Nîmes, 30000, France.
Carl Zeiss Meditec, Inc., 5300 Central Parkway, Dublin, CA 94568, USA.
Biomed Opt Express. 2023 Jun 12;14(7):3203-3212. doi: 10.1364/BOE.487217. eCollection 2023 Jul 1.
Metrics of retinal image quality predict optimal refractive corrections and correlate with visual performance. To date, they do not predict absolutely the relative change in visual performance when aberrations change and therefore need to be a-posteriori rescaled to match relative measurements. Here we demonstrate that a recently proposed metric can be used to predict, in an absolute manner, changes in contrast sensitivity measurements with Sloan letters when aberrations change. Typical aberrations of young and healthy eyes (for a 6 mm pupil diameter) were numerically introduced, and we measured the resulting loss in contrast sensitivity of subjects looking through a 2 mm diameter pupil. Our results suggest that the metric can be used to corroborate measurements of visual performance in clinical practice, thereby potentially improving patient follow-ups.
视网膜图像质量指标可预测最佳屈光矫正,并与视觉性能相关。迄今为止,当像差发生变化时,它们并不能绝对预测视觉性能的相对变化,因此需要进行事后重新缩放以匹配相对测量值。在此,我们证明,最近提出的一种指标可用于绝对地预测当像差发生变化时,使用斯隆字母的对比度敏感度测量值的变化。通过数值模拟引入了年轻健康眼睛(瞳孔直径6毫米)的典型像差,我们测量了受试者通过2毫米直径瞳孔观察时对比度敏感度的相应损失。我们的结果表明,该指标可用于在临床实践中确证视觉性能的测量,从而有可能改善患者随访。