Suppr超能文献

3D T1加权快速自旋回波成像在颅内支架置入评估中的应用价值

Usefulness of 3D T1-Turbo Spin Echo Imaging for the Evaluation of Intracranial Stent Placement.

作者信息

Mizuno Hiroyuki, Aihara Masanori, Sato Koji, Negishi Chikashi, Sasaguchi Nobuo, Kurihara Hideyuki, Yoshimoto Yuhei

机构信息

Department of Neurosurgery, Gunma University Graduate School of Medicine, Maebashi, Gunma, Japan.

Department of Neurosurgery, National Hospital Organization Takasaki General Medical Center, Takasaki, Gunma, Japan.

出版信息

J Neuroendovasc Ther. 2023;17(1):1-7. doi: 10.5797/jnet.oa.2022-0039. Epub 2022 Oct 14.

Abstract

OBJECTIVE

Evaluation of intracranial stent placement by MRI suffers the problems of signal artifacts during time-of-flight MRA (TOF-MRA). Therefore, angiographic examination is required for detailed intravascular assessment of the stent placement site. Recently, 3D T1-turbo spin echo (3D-TSE) has been developed for evaluation of carotid artery stent placement. We investigated the use of the 3D-TSE imaging method for the evaluation of intracranial vascular stent placement.

METHODS

The subjects consisted of nine patients who underwent intracranial vascular stent placement between April 2015 and December 2019. Postoperatively, the lumens of the placed stents were measured by TOF-MRA, DSA, and 3D-TSE imaging. Analysis was performed by type of stent and placement site.

RESULTS

The stents used were Neuroform Atlas (3 patients), LVIS (3 patients), LVIS Jr (2 patients), and Integrity (1 patient). TOF-MRA of the stent placement site showed defects in the image or poor visualization in all nine patients, whereas 3D-TSE imaging visualized the lumen at the stent indwelling site in all patients. The blood vessel diameter measured by the DSA and 3D-TSE imaging exhibited positive correlations regardless of the stent type and placement site.

CONCLUSION

3D-TSE imaging allows visualization of the lumen of the site of an intracranial vascular stent, regardless of the type of stent or the vessel. Thus, this method may be useful for evaluating the vascular lumen of a lesion.

摘要

目的

通过磁共振成像(MRI)评估颅内支架置入情况时,时间飞跃磁共振血管造影(TOF-MRA)会出现信号伪影问题。因此,需要进行血管造影检查以对支架置入部位进行详细的血管内评估。最近,三维T1加权快速自旋回波(3D-TSE)已被开发用于评估颈动脉支架置入情况。我们研究了3D-TSE成像方法在评估颅内血管支架置入中的应用。

方法

研究对象包括2015年4月至2019年12月期间接受颅内血管支架置入的9例患者。术后,通过TOF-MRA、数字减影血管造影(DSA)和3D-TSE成像测量所置入支架的管腔。按支架类型和置入部位进行分析。

结果

使用的支架包括Neuroform Atlas(3例患者)、LVIS(3例患者)、LVIS Jr(2例患者)和Integrity(1例患者)。所有9例患者支架置入部位的TOF-MRA图像均显示有缺损或可视化不佳,而3D-TSE成像在所有患者中均能清晰显示支架置入部位的管腔。无论支架类型和置入部位如何,DSA和3D-TSE成像测量的血管直径均呈正相关。

结论

3D-TSE成像能够清晰显示颅内血管支架置入部位的管腔,无论支架类型或血管如何。因此,该方法可能有助于评估病变的血管管腔。