Suppr超能文献

一种新型压电辅助非手术牙周治疗:前瞻性病例系列

A Novel Piezoelectric-Assisted Non-Surgical Periodontal Treatment: A Prospective Case Series.

作者信息

Rotundo Roberto, Marini Lorenzo, Carere Mauro, Trezza Cinzia, Marras Giovanni, Nieri Michele, Pilloni Andrea

机构信息

Periodontology Unit, Vita-Salute San Raffaele University, 20132 Milan, Italy.

Section of Periodontology, Department of Dental and Maxillofacial Sciences, Sapienza, University of Rome, 00161 Rome, Italy.

出版信息

Dent J (Basel). 2023 Jul 20;11(7):178. doi: 10.3390/dj11070178.

Abstract

The purpose of this study was to evaluate the clinical efficacy of a non-surgical periodontal treatment using a piezoelectric power-driven device with a novel insert. Plaque index (PlI), bleeding on probing (BoP), probing depth (PD), recession depth (Rec) and clinical attachment level (CAL) were assessed at 6 weeks, 3 months and 6 months. Furthermore, tooth mobility and furcation involvement were recorded and chewing discomfort and dental hypersensitivity were evaluated. Eighteen stage I to IV periodontitis patients providing 437 teeth and 2622 sites in total were analyzed. At six weeks, CAL gain (0.4; < 0.0001), PD reduction (0.4; < 0.0001) and Rec increase (0.1; = 0.0029) were statistically significant. Similarly, the mean number of sites with PD > 4 mm and absence of BoP significantly decreased between baseline and 6 weeks (-12.7; < 0.0001). At this time point, the patient's chewing discomfort was also significantly diminished (1.4; = 0.0172). Conversely, no statistically significant changes were observed between 6 weeks and 3 months and between 3 months and 6 months for any of the clinical variables evaluated. In conclusion, within the limitation of this study, mechanical piezo-assisted non-surgical periodontal treatment in conjunction with an innovative tip resulted significantly efficacious to reduce pathological periodontal pockets, to gain clinical attachment and to reduce gingival inflammation.

摘要

本研究的目的是评估使用带有新型插入物的压电动力驱动装置进行非手术牙周治疗的临床疗效。在6周、3个月和6个月时评估菌斑指数(PlI)、探诊出血(BoP)、探诊深度(PD)、退缩深度(Rec)和临床附着水平(CAL)。此外,记录牙齿松动度和根分叉病变情况,并评估咀嚼不适和牙齿过敏。对18例I至IV期牙周炎患者共437颗牙齿和2622个位点进行了分析。在6周时,CAL增加(0.4;<0.0001)、PD降低(0.4;<0.0001)和Rec增加(0.1;=0.0029)具有统计学意义。同样,基线和6周之间,PD>4mm且无BoP的位点平均数量显著减少(-12.7;<0.0001)。在这个时间点,患者的咀嚼不适也显著减轻(1.4;=0.0172)。相反,在6周和3个月之间以及3个月和6个月之间,所评估的任何临床变量均未观察到统计学上的显著变化。总之,在本研究的局限性内,机械压电辅助非手术牙周治疗结合创新的尖端在减少病理性牙周袋、获得临床附着和减轻牙龈炎症方面具有显著疗效。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/913f/10378624/5fced16bdae8/dentistry-11-00178-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验