A new voltammetry method for the highly sensitive antibacterial drug ciprofloxacin (CIP) is presented using glassy carbon electrodes modified with hierarchical electrospun carbon nanofibers with NiCo nanoparticles (eCNF/CNT/NiCo-GCE). The use of a modified glassy carbon electrode in the form of hierarchical electrospun carbon nanofibers with NiCo nanoparticles (eCNF/CNT/NiCo) led to an LOD value as low as 6.0 µmol L with a measurement sensitivity of 3.33 µA µmol L. The described procedure was successfully applied for CIP determination in samples with complex matrices, such as urine or plasma, and also in pharmaceutical products and antibiotic discs with satisfactory recovery values ranging between 94-104%. The proposed electrode was characterised by great stability, with the possibility of use for about 4 weeks without any significant change in the CIP peak current. The repeatability of the CIP response on the eCNF/CNT/NiCo/GC is also very good; its value measured and expressed as RSD is equal to 2.4% for a CIP concentration of 0.025 µmol L (for 7 consecutive CIP voltammogram registrations). The procedure for electrode preparation is quick and simple and does not involve the use of expensive apparatus.

摘要

本文介绍了一种用于高灵敏度检测抗菌药物环丙沙星(CIP)的新伏安法,该方法使用了修饰有含镍钴纳米颗粒的分级电纺碳纳米纤维的玻碳电极(eCNF/CNT/NiCo-GCE)。采用含镍钴纳米颗粒的分级电纺碳纳米纤维形式的修饰玻碳电极(eCNF/CNT/NiCo),可实现低至6.0 µmol/L的检测限,测量灵敏度为3.33 µA/µmol/L。所描述的方法成功应用于尿液或血浆等复杂基质样品中CIP的测定,以及药品和抗生素药片中CIP的测定,回收率令人满意,在94%-104%之间。所提出的电极具有很高的稳定性,可使用约4周,CIP峰电流无任何显著变化。eCNF/CNT/NiCo/GC上CIP响应的重复性也非常好;对于0.025 µmol/L的CIP浓度(连续记录7次CIP伏安图),以相对标准偏差(RSD)表示的测量值为2.4%。电极制备过程快速简单,无需使用昂贵的仪器。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7cdd/10385619/1ffc91946904/membranes-13-00682-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验