The Health Information and Quality Authority (HIQA), Dublin, Ireland.
Eur Radiol. 2023 Dec;33(12):9469-9478. doi: 10.1007/s00330-023-09992-4. Epub 2023 Jul 28.
The aim of this work was to establish national diagnostic reference levels (DRLs) in Ireland and compare these to existing European DRLs where available. This work surveyed all radiological facilities providing radiography, mammography, and dual-energy x-ray absorptiometry (DXA) services in Ireland.
A list of common procedures and clinical tasks was established. A national database of service providers was used to identify the appropriate medical radiological facilities providing these services. These facilities were issued with an online survey. National DRLs were set as the 75th percentile of the distribution of median values obtained. A national median dose was also established. The broad categorisation of equipment type was also considered. Where differences between DRLs established using different detector types were deemed statistically significant, equipment-specific national DRLs were established.
National DRLs were established for 12 adult radiography projections. Equipment-specific (computed radiography and digital radiography) adult DRLs were established for four radiography projections. Paediatric DRLs were established for 11 radiography projections, including two based on clinical indications, for a range of paediatric weight categories. National DRLs were established for unilateral two-view mammography and breast tomosynthesis as well as for four DXA clinical indications and projections. All but one Irish DRL figure was found to be below or equal to European data.
This work provided a unique opportunity to establish national DRLs based on census data for a range of procedures and clinical tasks across radiography, mammography and DXA and compare these with European levels.
This work established national diagnostic reference levels (DRLs) based on census data for a range of procedures and clinical tasks across radiography, mammography and dual-energy x-ray absorptiometry. The establishment of national DRLs is an essential component in the optimisation of patient radiation dose.
• Diagnostic reference levels are easily measured quantities intended for use as an aid to optimise patient dose and to identify when levels of patient dose are unusually high. • Data from all medical radiological facilities in Ireland was obtained to establish national diagnostic reference level (DRL) values and national median dose values in radiography, x-ray breast imaging and dual-energy x-ray absorptiometry (DXA) scanning and these were compared to existing European DRLs where available. • National DRL values were established for the first time in breast tomosynthesis, DXA scanning, and paediatric radiography.
本研究旨在爱尔兰建立全国诊断参考水平(DRL),并在可能的情况下与现有的欧洲 DRL 进行比较。本研究调查了爱尔兰所有提供放射摄影、乳房 X 线摄影和双能 X 射线吸收法(DXA)服务的放射学设施。
建立了一份常见程序和临床任务清单。利用全国服务提供商数据库确定提供这些服务的适当医疗放射学设施。向这些设施发放了在线调查。将全国 DRL 设定为获得的中位数分布的第 75 个百分位数。还确定了全国中位数剂量。还考虑了设备类型的广泛分类。如果使用不同探测器类型确定的 DRL 之间存在统计学差异,则确定特定于设备的全国 DRL。
为 12 个成人放射摄影投影建立了全国 DRL。为四个放射摄影投影建立了特定于设备的(计算机放射摄影和数字放射摄影)成人 DRL。为 11 个放射摄影投影建立了儿科 DRL,包括两个基于临床指征的用于一系列儿科体重类别的投影。为单侧双视图乳房 X 线摄影和乳房断层合成术以及四个 DXA 临床指征和投影建立了全国 DRL。除一个外,所有爱尔兰 DRL 数据都低于或等于欧洲数据。
这项工作为基于普查数据为放射摄影、乳房 X 线摄影和 DXA 中的一系列程序和临床任务建立全国 DRL 并将其与欧洲水平进行比较提供了独特的机会。
本研究基于普查数据为放射摄影、乳房 X 线摄影和双能 X 射线吸收法中的一系列程序和临床任务建立了全国诊断参考水平(DRL)。全国 DRL 的建立是优化患者辐射剂量的重要组成部分。
诊断参考水平是易于测量的量,旨在用作优化患者剂量的辅助手段,并确定患者剂量水平是否异常高。
从爱尔兰所有医疗放射学设施获得数据,以建立放射摄影、X 射线乳房成像和双能 X 射线吸收法(DXA)扫描的全国诊断参考水平(DRL)值和全国中位数剂量值,并在可能的情况下与现有的欧洲 DRL 进行比较。
首次在乳房断层合成术、DXA 扫描和儿科放射摄影中建立了全国 DRL 值。