Suppr超能文献

桦树诱发的过敏性鼻炎:鼻腔过敏原激发试验、环境舱及花粉季节期间的暴露结果。

Birch-induced allergic rhinitis: Results of exposure during nasal allergen challenge, environmental chamber, and pollen season.

作者信息

Gherasim Alina, Dietsch Frank, Beck Marine, Domis Nathalie, de Blay Frederic

机构信息

ALYATEC Environmental Exposure Chamber, 1 place de l'Hôpital, Strasbourg, France.

Chest Diseases Department, Strasbourg University Hospital, Strasbourg, France.

出版信息

World Allergy Organ J. 2023 Jul 15;16(7):100801. doi: 10.1016/j.waojou.2023.100801. eCollection 2023 Jul.

Abstract

BACKGROUND

Pollen variation can affect field study data quality. Nasal allergen challenge (NAC) is considered the gold standard for evaluating allergic rhinitis, while environmental exposure chambers (EECs) are mainly used in phase 2 drug development studies. We aimed to study birch-induced allergic rhinitis under 3 different conditions.

METHODS

This study included 30 participants allergic to birch pollen, based on birch skin prick test, specific immunoglobulin E (IgE), and positive NAC. Participants were exposed to placebo twice, followed by 2 consecutive 4-h birch airborne exposures, repeated on 2 occasions to evaluate reproducibility and priming effect. Nasal response was defined as total corrected nasal symptom score (ΔTNSS) ≥ 5 during NAC and EEC. The primary end-point was to measure TNSS during the last 2 h of first allergen exposure. TNSS was also analyzed during natural exposure.

RESULTS

The dose most commonly yielding positive TNSS during NAC was 175.2 ng/200 μL. Eighteen participants experienced ΔTNSS ≥5 during the last 2 h of the first exposure, whereas 21 had positive responses at all 4 exposures. Mean ΔTNSS was 1 with placebo versus 6 with birch. Exposures were reproducible, with no observed priming effect. Airborne Bet v 1 was 25 ng/m, while the pollen measurement was 279/m during pollen season. TNSS reached 5 in 67.9% of participants during peak pollen season.

CONCLUSION

EEC outcomes were similar to those obtained with NAC and natural exposure, suggesting the usefulness of EEC in allergic rhinitis studies. The primary end-point was reached, as 60% of participants experienced nasal responses.

摘要

背景

花粉变异会影响现场研究数据质量。鼻过敏原激发试验(NAC)被认为是评估过敏性鼻炎的金标准,而环境暴露舱(EEC)主要用于2期药物研发研究。我们旨在研究3种不同条件下桦树诱发的过敏性鼻炎。

方法

本研究纳入了30名对桦树花粉过敏的参与者,依据桦树皮肤点刺试验、特异性免疫球蛋白E(IgE)以及阳性NAC结果确定。参与者接受两次安慰剂暴露,随后连续进行2次4小时的桦树气传暴露,重复2次以评估可重复性和激发效应。鼻反应定义为NAC和EEC期间总校正鼻症状评分(ΔTNSS)≥5。主要终点是在首次过敏原暴露的最后2小时测量TNSS。还对自然暴露期间的TNSS进行了分析。

结果

NAC期间最常产生阳性TNSS的剂量为175.2 ng/200 μL。18名参与者在首次暴露的最后2小时出现ΔTNSS≥5,而21名参与者在所有4次暴露中均有阳性反应。安慰剂暴露时平均ΔTNSS为1,桦树暴露时为6。暴露具有可重复性,未观察到激发效应。气传Bet v 1为25 ng/m,花粉季节花粉测量值为279/m。花粉季节高峰期67.9%的参与者TNSS达到5。

结论

EEC的结果与NAC和自然暴露获得的结果相似,表明EEC在过敏性鼻炎研究中有用。达到了主要终点,因为60%的参与者出现了鼻反应。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8e0a/10384658/8b5d3d01e231/gr1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验