Arch Pathol Lab Med. 1986 Jun;110(6):520-2.

PMID:3754725
Abstract

To evaluate the necessity of duplicate testing for prothrombin times (PTs) and activated partial thromboplastin times (APTTs), the range of differences between duplicate sample results was analyzed on a widely used automated photo-optical coagulation instrument. Specimens with coagulation test times ranging from normal to threefold above the reference range were included. Of 1,610 PTs and 1,023 APTTs, approximately 95% of duplicates differed by 0.2 s or less and 2.0 s or less, respectively. Approximately 99% of PTs and APTTs differed by 0.4 s or less and 4.0 s or less, respectively; there were three PT and 16 APTT specimens whose duplicates differed by a greater time interval and also by more than 5% of the mean. Thus, PT and APTT testing on automated instrumentation is very precise, but occasional inaccurate single measurements could lead to errors in diagnosis or therapy.

摘要

为评估凝血酶原时间(PT)和活化部分凝血活酶时间(APTT)重复检测的必要性,我们在一台广泛使用的自动光学凝血分析仪上分析了重复样本结果之间的差异范围。纳入了凝血检测时间从正常到高于参考范围三倍的样本。在1610次PT检测和1023次APTT检测中,约95%的重复检测结果差异分别在0.2秒或以内和2.0秒或以内。约99%的PT和APTT检测结果差异分别在0.4秒或以内和4.0秒或以内;有3次PT检测和16次APTT检测的样本,其重复检测结果的时间间隔差异更大,且差异超过平均值的5%。因此,自动仪器上的PT和APTT检测非常精确,但偶尔不准确的单次测量可能导致诊断或治疗错误。