Gong Eun Jeong, Lim Hyun, Lee Sang Jin, Kim Do Hoon
Department of Internal Medicine, Hallym University College of Medicine, Chuncheon, Korea.
Division of Gastroenterology, Department of Internal Medicine, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, Korea.
J Gastric Cancer. 2023 Jul;23(3):451-461. doi: 10.5230/jgc.2023.23.e22.
Endoscopic submucosal dissection (ESD) is an effective treatment for early gastrointestinal neoplasms. However, this is a time-consuming procedure requiring various devices. This study aimed to evaluate the efficacy and safety of the ClearCut™ Knife H-type, which is an integrated needle-tipped and insulated-tipped (IT) knife.
Between July 2020 and September 2021, 99 patients with gastric epithelial neoplasms scheduled for ESD at three tertiary care hospitals were randomly assigned to H-knife (ClearCut™ Knife H-type) or IT-knife (conventional IT knife) groups. Procedure times, therapeutic outcomes, and adverse events were analyzed.
A total of 98 patients (50 in the H-knife group and 48 in the IT-knife group) were analyzed. The median total procedure time was 11.9 minutes (range, 4.4-47.2 minutes) in the H-knife group and 12.7 minutes (range, 5.2-137.7 minutes) in the IT-knife group (P=0.209). Unlike the IT-knife group, which required additional devices in all cases, no additional devices were used in the H-knife group (P<0.001). En-bloc resection was performed for all lesions in both groups. The incidence of adverse events was not significantly different between groups (4.0% in the H-knife group vs. 8.3% in the IT-knife group; P=0.431).
The newly developed hybrid device, the ClearCut™ Knife H-type, had comparable efficacy to the conventional IT knife for gastric ESD.
Clinical Research Information Service Identifier: KCT0005164.
内镜黏膜下剥离术(ESD)是治疗早期胃肠道肿瘤的有效方法。然而,这是一个耗时的过程,需要各种设备。本研究旨在评估ClearCut™刀H型(一种集成了针状尖端和绝缘尖端的IT刀)的疗效和安全性。
2020年7月至2021年9月期间,在三家三级医疗机构计划接受ESD治疗的99例胃上皮肿瘤患者被随机分为H刀组(ClearCut™刀H型)和IT刀组(传统IT刀)。分析手术时间、治疗结果和不良事件。
共分析了98例患者(H刀组50例,IT刀组48例)。H刀组的中位总手术时间为11.9分钟(范围4.4 - 47.2分钟),IT刀组为12.7分钟(范围5.2 - 137.7分钟)(P = 0.209)。与在所有病例中都需要额外设备的IT刀组不同,H刀组未使用额外设备(P < 0.001)。两组所有病变均进行了整块切除。两组间不良事件发生率无显著差异(H刀组为4.0%,IT刀组为8.3%;P = 0.431)。
新开发的混合设备ClearCut™刀H型在胃ESD方面与传统IT刀具有相当的疗效。
临床研究信息服务标识符:KCT0005164。