• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Design and validation of an automated hydrostatic weighing system.

作者信息

McClenaghan B A, Rocchio L

出版信息

Med Sci Sports Exerc. 1986 Aug;18(4):479-84.

PMID:3755792
Abstract

The purpose of this study was to design and evaluate the validity of an automated technique to assess body density using a computerized hydrostatic weighing system. An existing hydrostatic tank was modified and interfaced with a microcomputer equipped with an analog-to-digital converter. Software was designed to input variables, control the collection of data, calculate selected measurements, and provide a summary of the results of each session. Validity of the data obtained utilizing the automated hydrostatic weighing system was estimated by: evaluating the reliability of the transducer/computer interface to measure objects of known underwater weight; comparing the data against a criterion measure; and determining inter-session subject reliability. Values obtained from the automated system were found to be highly correlated with known underwater weights (r = 0.99, SEE = 0.0060 kg). Data concurrently obtained utilizing the automated system and a manual chart recorder were also found to be highly correlated (r = 0.99, SEE = 0.0606 kg). Inter-session subject reliability was determined utilizing data collected on subjects (N = 16) tested on two occasions approximately 24 h apart. Correlations revealed high relationships between measures of underwater weight (r = 0.99, SEE = 0.1399 kg) and body density (r = 0.98, SEE = 0.00244 g X cm-1). Results indicate that a computerized hydrostatic weighing system is a valid and reliable method for determining underwater weight.

摘要

相似文献

1
Design and validation of an automated hydrostatic weighing system.
Med Sci Sports Exerc. 1986 Aug;18(4):479-84.
2
An automated real time underwater weighing system.
Med Sci Sports Exerc. 1994 Mar;26(3):383-91.
3
Bioelectric impedance and hydrostatic weighing with and without head submersion in persons who are morbidly obese.病态肥胖者在头部浸没和未浸没情况下的生物电阻抗和水下称重。
J Am Diet Assoc. 1998 Aug;98(8):869-75. doi: 10.1016/S0002-8223(98)00201-6.
4
Development of an underwater weighing system for determining body composition.
Biomed Sci Instrum. 1997;34:363-7.
5
A simple inexpensive method for estimating underwater weight.一种简单且低成本的水下称重估算方法。
Br J Sports Med. 1978 Mar;12(1):33-6.
6
Validity of near infrared body composition analysis in children and adolescents.近红外身体成分分析在儿童和青少年中的有效性
Med Sci Sports Exerc. 1993 Oct;25(10):1185-91.
7
Validity and reliability of the BOD POD® S/T tracking system.BOD POD® S/T 追踪系统的有效性和可靠性。
Int J Sports Med. 2010 Oct;31(10):704-8. doi: 10.1055/s-0030-1255111. Epub 2010 Jul 8.
8
A hydrostatic weighing method using total lung capacity and a small tank.一种使用肺总量和小型水箱的水下称重法。
Br J Sports Med. 1986 Mar;20(1):17-21. doi: 10.1136/bjsm.20.1.17.
9
Prediction of percent body fat in adult males using dual energy x-ray absorptiometry, skinfolds, and hydrostatic weighing.使用双能X线吸收法、皮褶厚度测量法和水下称重法预测成年男性的体脂百分比。
Med Sci Sports Exerc. 1993 Apr;25(4):528-35.
10
Validity of anthropometric equations for the estimation of body density in adolescent athletes.用于估算青少年运动员身体密度的人体测量方程的有效性。
Med Sci Sports Exerc. 1984;16(1):77-81.