Abstract

This study aimed to assess the validity, reliability, and sensitivity of mobile applications for assessing change-of-direction speed (CODS) performance. Thirty college athletes performed two Illinois CODS tests during one session. Assessments were carried out simultaneously using six devices (the CODTimer app, Seconds Count app, StopwatchCamera app, two analog stopwatches, and timing gates). Validity analyses included Pearson's product-moment correlation analysis, a linear regression model, and Bland-Altman plots. Reliability analyses included the intraclass correlation coefficient (ICC), the coefficient of variation (CV%), and the paired-sample t test. Sensitivity analyses included the typical error and smallest worthwhile change (SWC). The results showed that validity, reliability, and sensitivity values were higher for the CODTimer app (r = 0.99, R = 0.99, mean bias = -0.03 ± 0.10, CV% = 3.21, ICC = 0.89, SWC rating: good, p = 0.84) and the Seconds Count app (r = 0.99, R = 0.99, mean bias = -0.03 ± 0.08, CV% = 3.28, ICC = 0.88, SWC rating: good, p = 0.84) relative to the StopwatchCamera app (r = 0.98, R = 0.97, mean bias = -0.11 ± 0.22, CV% = 3.43, ICC = 0.86, SWC rating: marginal, p = 0.10), Analog Stopwatch 1 (r = 0.98, R = 0.96, mean bias = -0.09 ± 0.42, CV% = 2.95, ICC = 0.90, SWC rating: good, p = 0.91), and Analog Stopwatch 2 (r = 0.99, R = 0.97, mean bias = -0.12 ± 0.88, CV% = 3.51, ICC = 0.87, SWC rating: marginal, p = 0.96). In conclusion, compared to timing gates, the CODTimer app and Seconds Count app provided lower measurement bias and higher sensitivity for assessing CODS performance.

摘要

本研究旨在评估用于评估变向速度(CODS)表现的移动应用程序的有效性、可靠性和敏感性。30名大学运动员在同一时段内进行了两次伊利诺伊变向速度测试。使用六种设备(CODTimer应用程序、Seconds Count应用程序、StopwatchCamera应用程序、两块模拟秒表和计时门)同时进行评估。有效性分析包括皮尔逊积矩相关分析、线性回归模型和布兰德-奥特曼图。可靠性分析包括组内相关系数(ICC)、变异系数(CV%)和配对样本t检验。敏感性分析包括典型误差和最小有价值变化(SWC)。结果显示,相对于StopwatchCamera应用程序(r = 0.98,R = 0.97,平均偏差 = -0.11 ± 0.22,CV% = 3.43,ICC = 0.86,SWC评级:临界,p = 0.10)、模拟秒表1(r = 0.98,R = 0.96,平均偏差 = -0.09 ± 0.42,CV% = 2.95,ICC = 0.90,SWC评级:良好,p = 0.91)和模拟秒表2(r = 0.99,R = 0.97,平均偏差 = -0.12 ± 0.88,CV% = 3.51,ICC = 0.87,SWC评级:临界,p = 0.96),CODTimer应用程序(r = 0.99,R = 0.99,平均偏差 = -0.03 ± 0.10,CV% = 3.21,ICC = 0.89,SWC评级:良好,p = 0.84)和Seconds Count应用程序(r = 0.99,R = 0.99,平均偏差 = -0.03 ± 0.08,CV% = 3.28,ICC = 0.88,SWC评级:良好,p = 0.84)具有更高的有效性、可靠性和敏感性值。总之,与计时门相比,CODTimer应用程序和Seconds Count应用程序在评估CODS表现时测量偏差更低且敏感性更高。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b27b/10407321/6b2ef5409529/JHK-88-167465-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验