Evrin Togay, Dabkowski Miroslaw, Pruc Michal, Hernik Jacek, Wieczorek Wojciech, Chabowski Lukasz, Wieczorek Pawel, Chmielewski Jaroslaw, Feduniw Stepan, Szarpak Lukasz
Department of Emergency Medicine, Medical Faculty, Ufuk University, 06510 Ankara, Turkey.
Research Unit, Polish Society of Disaster Medicine, 05-806 Warsaw, Poland.
J Clin Med. 2023 Aug 2;12(15):5074. doi: 10.3390/jcm12155074.
Airway management procedures, such as endotracheal intubation (ETI), pose a significant risk of aerosol generation, requiring robust personal protective equipment (PPE) against aerosol-generating procedures (AGP). This study aimed to assess the impact of PPE-AGP on intubation success rates, time to intubation, and glottic visualization using ETView and a standard Macintosh laryngoscope (MAC). A total of 52 physicians participated in this prospective, observational, randomized crossover study conducted in a medical simulation setting. Participants included COVID-19 patients with cardiac arrest scenarios with and without PPE-AGP who were intubated with ETView and MAC. During intubation without PPE-AGP, ETView showed a similar first-pass success rate (FPS) but had a shorter intubation time and better glottal hydration compared to MAC. In scenario B (with PPE-AGP), ETView outperformed MAC in FPS, initiation time, and glottic visualization. The use of PPE-AGP had little impact on ETView's performance. However, it negatively affected the Macintosh laryngoscope, reducing FPS and glottic visibility. Participants found intubation with ETView easier in both scenarios. In conclusion, as compared to the Macintosh laryngoscope, ETView demonstrated higher performance under the circumstances of the simulation, especially when PPE-AGP was used.
气道管理程序,如气管插管(ETI),会产生大量气溶胶,因此需要使用坚固的个人防护装备(PPE)来应对产生气溶胶的操作(AGP)。本研究旨在评估使用PPE进行AGP对插管成功率、插管时间以及使用ETView和标准麦氏喉镜(MAC)时声门可视化的影响。共有52名医生参与了在医学模拟环境中进行的这项前瞻性、观察性、随机交叉研究。参与者包括患有心脏骤停的COVID-19患者,在有和没有PPE-AGP的情况下使用ETView和MAC进行插管。在不使用PPE进行AGP的插管过程中,与MAC相比,ETView显示出相似的首次通过成功率(FPS),但插管时间更短,声门可视化效果更好。在场景B(使用PPE-AGP)中,ETView在FPS、开始时间和声门可视化方面优于MAC。使用PPE-AGP对ETView的性能影响不大。然而,它对麦氏喉镜有负面影响,降低了FPS和声门可见度。参与者发现在两种场景下使用ETView进行插管都更容易。总之,与麦氏喉镜相比,ETView在模拟环境中表现出更高的性能,尤其是在使用PPE-AGP时。