Suppr超能文献

烟囱式血管内动脉瘤修复术引发的肠系膜缺血:一例极其罕见并发症的报告。

Chimney endovascular aneurysm repair-induced mesenteric ischemia: a report of an extremely rare complication.

作者信息

Annuvolo Pierfrancesco Antonio, Pascucci Federico, Minelli Fabrizio, Natola Marco, Donati Tommaso, Tshomba Yamume

机构信息

Unit of Vascular Surgery, Fondazione Policlinico Universitario Gemelli IRCCS - Università Cattolica del Sacro Cuore, Rome, Italy.

出版信息

J Vasc Surg Cases Innov Tech. 2023 Jul 4;9(3):101259. doi: 10.1016/j.jvscit.2023.101259. eCollection 2023 Sep.

Abstract

The chimney endovascular aneurysm repair (Ch-EVAR) technique has progressively increased in popularity in the treatment of complex aortic aneurysms. However, the long-term results of this technique still must be assessed, especially in comparison to custom-made solutions. The patency of chimney grafts has always been one of the important issues with the Ch-EVAR technique. However, interactions between nonstented aortic side branches and chimney stent grafts have rarely been discussed. In the present case report, we describe a rare case of mesenteric ischemia due to superior mesenteric artery ostium coverage by the misalignment of a renal stent graft in a Ch-EVAR.

摘要

烟囱式血管腔内动脉瘤修复术(Ch-EVAR)在复杂主动脉瘤的治疗中越来越受欢迎。然而,该技术的长期效果仍有待评估,尤其是与定制解决方案相比。烟囱式移植物的通畅性一直是Ch-EVAR技术的重要问题之一。然而,非支架主动脉侧支与烟囱式支架移植物之间的相互作用很少被讨论。在本病例报告中,我们描述了一例罕见的肠系膜缺血病例,该病例是由于Ch-EVAR中肾支架移植物错位覆盖肠系膜上动脉开口所致。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d454/10413130/dd9dfa5383d8/gr1.jpg