Abstract

Driveline infection in patients with implantable left ventricular assist devices (LVAD) remains common and crucial. Once a driveline exit-site infection reaches the LVAD component, radical treatment such as LVAD exchange may become necessary, although the clinical results are unsatisfactory. The Jarvik 2000 device, which utilizes a postauricular cable, allows the driveline to exit the body behind the ear (postauricular) instead of through an abdominal site. Here, we report the case of a patient who had awaited heart transplantation for more than 6 years and had a critical driveline infection that almost reached the LVAD pump. The patient underwent a pump exchange using the Jarvik 2000 with a postauricular cable, with excellent results. It is a useful replacement option for patients with abdominal driveline infections, owing to its small pump pocket and the availability of an alternative pathway for the driveline.

摘要

植入式左心室辅助装置(LVAD)患者的 driveline 感染仍然很常见且至关重要。一旦 driveline 出口部位感染累及 LVAD 组件,可能就需要进行如更换 LVAD 等根治性治疗,尽管临床效果并不理想。Jarvik 2000 装置采用耳后电缆,使 driveline 从耳后(耳后)而非腹部部位穿出身体。在此,我们报告一例等待心脏移植超过 6 年且发生严重 driveline 感染、几乎累及 LVAD 泵的患者病例。该患者使用带有耳后电缆的 Jarvik 2000 进行了泵更换,效果极佳。由于其泵腔较小且 driveline 有替代通路,对于腹部 driveline 感染患者而言,它是一种有用的替代选择。

相似文献

1
Pump Exchange from a Left Ventricular Assist Device to a Jarvik 2000 with a Postauricular Cable Due to Abdominal Driveline Infection.
Yonago Acta Med. 2023 Jul 31;66(3):389-393. doi: 10.33160/yam.2023.08.007. eCollection 2023 Aug.
2
Jarvik 2000 with postauricular cable as destination therapy: first clinical case in Japan.
J Artif Organs. 2020 Mar;23(1):89-92. doi: 10.1007/s10047-019-01130-6. Epub 2019 Sep 13.
3
Low Incidence of Pump-Related Infections in Jarvik 2000 Ventricular Assist Device Recipients with a Subcostal Driveline Exit Site.
Tex Heart Inst J. 2019 Jun 1;46(3):179-182. doi: 10.14503/THIJ-15-5708. eCollection 2019 Jun.
4
Complex HeartWare left ventricular assist device infection treated with pump exchange: clinical alert for the driveline location.
J Artif Organs. 2021 Sep;24(3):377-381. doi: 10.1007/s10047-020-01245-1. Epub 2021 Jan 13.
5
Left ventricle assist devices and driveline's infection incidence: a single-centre experience.
J Artif Organs. 2018 Mar;21(1):52-60. doi: 10.1007/s10047-017-0997-y. Epub 2017 Oct 7.
6
The Jarvik 2000 is associated with less infections than the HeartMate left ventricular assist device.
Eur J Cardiothorac Surg. 2003 May;23(5):748-54; discussion 754-5. doi: 10.1016/s1010-7940(03)00073-3.
9
Late-onset driveline infections: the Achilles' heel of prolonged left ventricular assist device support.
Ann Thorac Surg. 2007 Aug;84(2):515-20. doi: 10.1016/j.athoracsur.2007.03.085.
10
A modified surgical technique for the Jarvik 2000 using a postauricular approach.
Surg Today. 2022 May;52(5):863-865. doi: 10.1007/s00595-021-02368-5. Epub 2021 Sep 4.

本文引用的文献

1
Complex HeartWare left ventricular assist device infection treated with pump exchange: clinical alert for the driveline location.
J Artif Organs. 2021 Sep;24(3):377-381. doi: 10.1007/s10047-020-01245-1. Epub 2021 Jan 13.
2
FDG PET/CT for Early Detection and Localization of Left Ventricular Assist Device Infection: Impact on Patient Management and Outcome.
JACC Cardiovasc Imaging. 2019 Apr;12(4):722-729. doi: 10.1016/j.jcmg.2018.01.024. Epub 2018 Mar 14.
3
Left ventricle assist devices and driveline's infection incidence: a single-centre experience.
J Artif Organs. 2018 Mar;21(1):52-60. doi: 10.1007/s10047-017-0997-y. Epub 2017 Oct 7.
4
Eighth annual INTERMACS report: Special focus on framing the impact of adverse events.
J Heart Lung Transplant. 2017 Oct;36(10):1080-1086. doi: 10.1016/j.healun.2017.07.005. Epub 2017 Jul 15.
5
Mechanical reliability of the Jarvik 2000 Heart.
Ann Thorac Surg. 2006 May;81(5):1752-8; discussion 1758-9. doi: 10.1016/j.athoracsur.2005.12.013.
6
The Jarvik 2000 is associated with less infections than the HeartMate left ventricular assist device.
Eur J Cardiothorac Surg. 2003 May;23(5):748-54; discussion 754-5. doi: 10.1016/s1010-7940(03)00073-3.
7
Postauricular percutaneous power delivery for permanent mechanical circulatory support.
J Thorac Cardiovasc Surg. 2002 May;123(5):977-83. doi: 10.1067/mtc.2002.121045.
8
Long-term use of a left ventricular assist device for end-stage heart failure.
N Engl J Med. 2001 Nov 15;345(20):1435-43. doi: 10.1056/NEJMoa012175.
9
LVAD power delivery: a percutaneous approach to avoid infection.
Ann Thorac Surg. 1998 Feb;65(2):470-3. doi: 10.1016/s0003-4975(97)01343-x.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验