Suppr超能文献

注射器未充满对静脉血气分析质量的影响。

Effect of syringe underfilling on the quality of venous blood gas analysis.

机构信息

Section of Clinical Biochemistry and School of Medicine, University of Verona, Verona, Italy.

Department of Haematology, Sydney Centres for Thrombosis and Haemostasis, Institute of Clinical Pathology and Medical Research (ICPMR), NSW Health Pathology, Westmead Hospital, Westmead, NSW, Australia.

出版信息

Diagnosis (Berl). 2023 Sep 5;11(1):91-96. doi: 10.1515/dx-2023-0096. eCollection 2024 Feb 1.

Abstract

OBJECTIVES

There is limited information on the influence of collecting small amounts of blood on the quality of blood gas analysis. Therefore, the purpose of this study was to investigate the effects of different degrees of underfilling of syringes on test results of venous blood gas analysis.

METHODS

Venous blood was collected by venipuncture from 19 healthcare workers in three 1.0 mL syringes for blood gas analysis, by manually aspirating different volumes of blood (i.e., 1.0, 0.5 and 0.25 mL). Routine blood gas analysis was then immediately performed with GEM Premier 5,000. The results of the two underfilled syringes were compared with those of the reference syringe filled with appropriate blood volume.

RESULTS

The values of most assayed parameters did not differ significantly in the two underfilled syringes. Statistically significant variations were found for lactate, hematocrit and total hemoglobin, the values of which gradually increased as the fill volume diminished, as well as for sodium concentration, which decreased in both insufficiently filled blood gas syringes. The bias was clinically meaningful for lactate in syringe filled with 0.25 mL of blood, and for hematocrit, total hemoglobin and sodium in both syringes containing 0.5 and 0.25 mL of blood.

CONCLUSIONS

Collection of smaller volumes of venous blood than the specified filling volume in blood gas syringes may have an effect on the quality of some test results, namely lactate, hematocrit, total hemoglobin and sodium. Specific indications must be given for standardizing the volume of blood to be collected within these syringes.

摘要

目的

关于少量采血对血气分析质量的影响,相关信息有限。因此,本研究旨在探讨注射器不同程度未注满对静脉血气分析检测结果的影响。

方法

19 名医护人员分别用 3 个 1.0mL 注射器经静脉穿刺采集血液进行血气分析,手动抽吸不同体积的血液(即 1.0、0.5 和 0.25mL)。随后立即用 GEM Premier 5000 进行常规血气分析。将两个未注满的注射器的结果与适当注满血容量的参考注射器的结果进行比较。

结果

在两个未注满的注射器中,大多数检测参数的测定值无显著差异。乳酸、红细胞压积和总血红蛋白的测定值逐渐降低,填充量减少,钠离子浓度在两个血气注射器中均降低,差异具有统计学意义。在填充 0.25mL 血液的注射器中,乳酸的偏差具有临床意义,在填充 0.5 和 0.25mL 血液的两个注射器中,红细胞压积、总血红蛋白和钠离子的偏差也具有临床意义。

结论

与血气注射器规定的填充量相比,采集的静脉血量较少可能会影响一些检测结果的质量,即乳酸、红细胞压积、总血红蛋白和钠离子。必须为规范这些注射器内采集的血液量给出具体的指示。