Landon M B, Cembrowski G S, Gabbe S G
Am J Obstet Gynecol. 1986 Oct;155(4):717-21. doi: 10.1016/s0002-9378(86)80005-9.
Home glucose monitoring with the use of reflectance meters is an important adjunct in the care of pregnant women with insulin-dependent diabetes. The accuracy of reflectance meters for the assay of capillary glucose specimens has been well documented. The present preliminary study was undertaken to determine the utility of outpatient screening for gestational diabetes mellitus with the use of a reflectance meter (Accu-Chek, Boehringer Mannheim Co.). One hundred twenty-five patients in our high-risk practice had a standard 50 gm glucose load at 26 to 28 weeks' gestation. Capillary glucose values were measured on site with the Accu-Chek. Venous plasma glucose levels were measured by the central laboratory chemistry analyzer. While the laboratory (x) and meter (y) glucose determinations between the two sets of values were highly correlated (R = 0.89, p less than 0.001), there was a significant difference in their average values (x = 111.74, y = 136.35, p less than 0.0001). With the use of a receiver operator characteristic curve, a meter value of 160 mg/dl was determined as the optimal threshold for performing a 3-hour glucose tolerance test. The sensitivity and specificity with the use of a meter value of 160 mg/dl were 93% and 96%, respectively, for detecting an abnormal screening test in venous plasma (greater than or equal to 135 mg/dl). A total of 32 glucose tolerance tests were performed, with four patients included who had venous values less than 135 mg/dl. All eight patients with gestational diabetes mellitus were correctly identified. These data suggest that a glucose reflectance meter can be used for accurate outpatient screening of gestational diabetes mellitus. The potential advantages of capillary blood glucose screening include both cost and efficiency. Patients with abnormal screening values can be promptly identified and scheduled for a follow-up 3-hour glucose tolerance test.
使用反射仪进行家庭血糖监测是护理胰岛素依赖型糖尿病孕妇的一项重要辅助手段。反射仪检测毛细血管血糖标本的准确性已有充分记录。本初步研究旨在确定使用反射仪(罗氏活力型血糖仪,勃林格殷格翰公司)进行门诊筛查妊娠期糖尿病的效用。我们高危诊所的125名患者在妊娠26至28周时接受了标准的50克葡萄糖负荷试验。使用罗氏活力型血糖仪在现场测量毛细血管血糖值。静脉血浆葡萄糖水平由中心实验室化学分析仪测量。虽然两组值之间实验室(x)和血糖仪(y)的血糖测定高度相关(R = 0.89,p < 0.001),但它们的平均值存在显著差异(x = 111.74,y = 136.35,p < 0.0001)。使用受试者工作特征曲线,确定血糖仪值160 mg/dl为进行3小时葡萄糖耐量试验的最佳阈值。对于检测静脉血浆中异常筛查试验(大于或等于135 mg/dl),使用血糖仪值160 mg/dl时的敏感性和特异性分别为93%和96%。共进行了32次葡萄糖耐量试验,其中包括4名静脉值低于135 mg/dl的患者。所有8例妊娠期糖尿病患者均被正确识别。这些数据表明,血糖反射仪可用于准确的门诊筛查妊娠期糖尿病。毛细血管血糖筛查的潜在优势包括成本和效率。筛查值异常的患者可以迅速被识别并安排进行后续的3小时葡萄糖耐量试验。