Suppr超能文献

一种自密封透析假体。同轴双聚四氟乙烯-硅树脂移植物。

A self-sealing dialysis prosthesis. Coaxial double PTFE-silicone graft.

作者信息

Schanzer H, Martinelli G P, Bock G, Peirce E C

出版信息

Ann Surg. 1986 Nov;204(5):574-9. doi: 10.1097/00000658-198611000-00011.

Abstract

The performance of a new dialysis prosthesis designed to self-seal after puncture was tested ex vivo and in vivo. It consists of two coaxial polytetrafluoroethylene tubes (PTFE), the space between them filled with silicone rubber sealant (PTFE-sil). Ex vivo: Three PTFE-sil, three double PTFE (without silicone), and three single PTFE grafts were placed sequentially between scribner shunts in the hind limb of four dogs. Bleeding on puncturing with an 18-gauge needle was measured for 30 seconds. PTFE-sil bled less than the controls (g): PTFE-sil; 16 +/- 18; double PTFE: 32 +/- 10; single PTFE: 52 +/- 19 (p less than 0.001). In vivo: Six PTFE-sil and five single PTFE grafts were interposed between the carotid artery and jugular vein of dogs and were punctured with a 16-gauge needle on days 1, 3, and 7. Bleeding was measured through an incision over the puncture site at 5 minutes. In 11 punctures of PTFE-sil, there was no bleeding; three bled less than 20 g. In 13 control punctures, none bled less than 70 g. Patency: Grafts were studied for patency in arteriovenous (AV) fistulas in 34 dogs. Each dog received a PTFE-sil graft in one groin and a single PTFE control graft in the other. At 4 months, patency rates were: PTFE-sil, 84%; single PTFE, 87% (NS). Four months after implantation, hemostasis after puncture in PTFE-sil grafts required 70 +/- 49 seconds versus 207 +/- 48 seconds for PTFE grafts (p less than 0.005). In conclusion, PTFE-sil grafts are self-sealing, can be used immediately after implantation, and need minimal compression after needle removal.

摘要

对一种设计用于穿刺后能自我封闭的新型透析假体进行了体外和体内测试。它由两根同轴的聚四氟乙烯管(PTFE)组成,它们之间的空间填充有硅橡胶密封剂(PTFE - sil)。体外测试:将三根PTFE - sil、三根双层PTFE(无硅橡胶)和三根单层PTFE移植物依次置于四只狗后肢的斯克里布纳分流器之间。用18号针穿刺后测量30秒的出血量。PTFE - sil的出血量少于对照组(克):PTFE - sil为16±18;双层PTFE为32±10;单层PTFE为52±19(p<0.001)。体内测试:将六根PTFE - sil和五根单层PTFE移植物置于狗的颈动脉和颈静脉之间,并在第1、3和7天用16号针进行穿刺。在穿刺后5分钟通过穿刺部位上方的切口测量出血量。在对PTFE - sil进行的11次穿刺中,没有出血情况;三次出血量少于20克。在13次对照穿刺中,没有一次出血量少于70克。通畅性:对34只狗动静脉(AV)瘘管中的移植物通畅性进行了研究。每只狗在一个腹股沟接受一根PTFE - sil移植物,在另一个腹股沟接受一根单层PTFE对照移植物。在4个月时,通畅率分别为:PTFE - sil为84%;单层PTFE为87%(无显著差异)。植入4个月后,PTFE - sil移植物穿刺后的止血时间为70±49秒,而PTFE移植物为207±48秒(p<0.005)。总之,PTFE - sil移植物能自我封闭,植入后可立即使用,拔针后只需极少的压迫。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/356c/1251342/ddc4690fd783/annsurg00093-0083-a.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验